Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis.

A Jónsson1, A Borg, P Hannesson, K Herrlin, K Jonsson, M Sloth, H Petterson.   

Abstract

In a prospective investigation the diagnostic accuracy of film-screen and digital radiography in rheumatoid arthritis of hands was compared. Seventy hands of 36 patients with established rheumatoid arthritis were included in the study. Each of 11 joints in every hand was evaluated regarding the following radiologic parameters: soft tissue swelling, joint space narrowing, erosions and periarticular osteopenia. The digital images were obtained with storage phosphor image plates and evaluated in 2 forms; as digital hard-copy on film and on a monitor of an interactive workstation. The digital images had a resolution of either 3.33 or 5.0 lp/mm. ROC curves were constructed and comparing the area under the curves no significant difference was found between the 3 different imaging forms in either resolution group for soft tissue swelling, joint space narrowing and erosions. The film-screen image evaluation of periarticular osteopenia was significantly better than the digital hard-copy one in the 3.33 lp/mm resolution group, but no significant difference was found in the 5.0 lp/mm group. These results support the view that currently available digital systems are capable of adequate diagnostic performance.

Entities:  

Mesh:

Year:  1994        PMID: 8011377

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.

Authors:  K Eklund; K Jonsson; G Lindblom; B Lundin; J Sanfridsson; M Sloth; B Sivberg
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

Review 2.  [Quantitative imaging in rheumatoid arthritis: from scoring to measurement].

Authors:  P Peloschek; G Langs; A Valentinitsch; M Bubale; T Schlager; C Müller-Mang; F Kainberger
Journal:  Radiologe       Date:  2006-05       Impact factor: 0.635

3.  Establishing the level of digitization for wrist and hand radiographs for the third National Health and Nutrition Examination Survey.

Authors:  Y Ostchega; L R Long; G H Goh; R Hirsch; L D Ma; W W Scott; W Johnson; G R Thoma
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

4.  Subjective quality assessment of computed radiography hand images.

Authors:  C A Britton; O F Gabriele; T S Chang; J D Towers; D A Rubin; W F Good; D Gur
Journal:  J Digit Imaging       Date:  1996-02       Impact factor: 4.056

Review 5.  The value of current developments in radiology to the accident and emergency department--a pictorial review.

Authors:  D C Lloyd
Journal:  J Accid Emerg Med       Date:  1997-11

6.  Internet hand x-rays: A comparison of joint space narrowing and erosion scores (Sharp/Genant) of plain versus digitized x-rays in rheumatoid arthritis patients.

Authors:  Hector O Arbillaga; Gregory P Montgomery; Luis P Cabarrus; Margaret M Watson; Liam Martin; Steven M Edworthy
Journal:  BMC Musculoskelet Disord       Date:  2002-04-30       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.