Literature DB >> 27408505

Evaluation of lower limb axial alignment using digital radiography stitched films in pre-operative planning for total knee replacement.

Michael J Neil1, Jereme B Atupan1, Juan Paulo L Panti1, Robert A J Massera1, Stewart Howard2.   

Abstract

BACKGROUND: For patients with knee osteoarthritis, even slight anatomical variations in the femur or the tibia could affect total limb alignment during total knee replacement (TKR). Our hypothesis implies that the femoral valgus correction angle (VCA) in patients indicated for TKR, is variable and higher than the reported norm of 6° utilized in most intramedullary instrumentation systems, and that tibial bowing may result to a disparity of the tibial mechanical axis to the anatomical axis.
METHODS: Our study is a retrospective review of 216 pre-operative arthritic knees, which investigated the lower limb axial alignment using digitally-stitched films. Patients excluded from the study are those with history of previous tibial or femoral osteotomy, secondary gonarthrosis, rheumatoid arthritis, previous femoral or tibial fracture, patients for bilateral TKR, or history of hip surgery.
RESULTS: The mean age was 68-years old (range 39-86 years). The mean VCA was 7° (4.7-9.3) for men and 6.6° (4.9-9) for women. However, 71 patients (33%) had more than 7° VCA. Subsequently, 46 patients (21%) had tibial bowing producing an angle >1.5° between its mechanical and anatomic axis.
CONCLUSIONS: The 6° standard when used as a guide may result in suboptimal prosthesis positioning during conventional TKR surgery. Therefore our findings suggest that the femoral valgus correction angle has a broad range, and using standard femoral intramedullary guides should not be overlooked.

Entities:  

Keywords:  Digital radiography; Total knee replacement; Valgus correction angle; Whole leg radiography

Year:  2016        PMID: 27408505      PMCID: PMC4930336          DOI: 10.1016/j.jor.2016.06.013

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  35 in total

1.  Radiologic analysis of the tibial intramedullary canal in Chinese varus knees: implications in total knee arthroplasty.

Authors:  P S Ko; M K Tio; C M Ban; Y K Mak; F K Ip; J J Lam
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

2.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

3.  Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images.

Authors:  Adrian V Specogna; Trevor B Birmingham; Jerome J DaSilva; Jaques S Milner; Jacqueline Kerr; Michael A Hunt; Ian C Jones; Thomas R Jenkyn; Peter J Fowler; J Robert Giffin
Journal:  J Knee Surg       Date:  2004-10       Impact factor: 2.757

4.  Improved method for planning intramedullary guiding rod entry point in total knee arthroplasty.

Authors:  Jianlin Xiao; Chenyu Wang; Lanyu Zhu; Xuezhou Li; Tong Liu; Qingyu Wang; Yanguo Qin
Journal:  Arch Orthop Trauma Surg       Date:  2014-02-12       Impact factor: 3.067

5.  Radiographic analysis of the axial alignment of the lower extremity.

Authors:  J R Moreland; L W Bassett; G J Hanker
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

6.  The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis.

Authors:  Jiann Jong Liau; Cheng Kung Cheng; Chun Hsiung Huang; Wai Hee Lo
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-02       Impact factor: 2.063

7.  Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program.

Authors:  Elizabeth A Sled; Lisa M Sheehy; David T Felson; Patrick A Costigan; Miu Lam; T Derek V Cooke
Journal:  Rheumatol Int       Date:  2009-11-01       Impact factor: 2.631

8.  Computer-assisted total knee arthroplasty for arthritis with extra-articular deformity.

Authors:  Arun Mullaji; Gautam M Shetty
Journal:  J Arthroplasty       Date:  2009-07-04       Impact factor: 4.757

9.  Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.

Authors:  S H Yang; T K Liu
Journal:  J Formos Med Assoc       Date:  1998-08       Impact factor: 3.282

10.  Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs.

Authors:  J Sailer; M Scharitzer; P Peloschek; A Giurea; H Imhof; S Grampp
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315