Literature DB >> 9888764

Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: a subjective comparison.

D W Piraino1, W J Davros, M Lieber, B J Richmond, J P Schils, M P Recht, P N Grooff, G H Belhobek.   

Abstract

OBJECTIVE: The purpose of this study was to subjectively compare the visibility of normal anatomy of the hands and feet using selenium-based digital radiography versus conventional film-screen (100-speed) radiography. SUBJECTS AND METHODS: Digital and film-screen images of the hands and feet of 24 patients were obtained without an antiscatter grid using identical X-ray exposure. Each pair of images was evaluated independently by five experienced radiologists for visibility of normal anatomy using a six-point rating scale. Soft tissues, cortical bone, and trabeculae were evaluated. For each observer, "equivalence" was defined as a mean difference in image quality of less than 1 unit on the 0-5 scale used in the study. Paired t tests were also performed to determine whether the average visibility rating of one technique was statistically superior to that of the other at a .05 level of significance for each observer and at each anatomic landmark.
RESULTS: In all categories, selenium-based digital images were rated equivalent to film-screen images by the five observers. Using the sum of the nine landmarks, four of the five observers rated the quality of selenium-based digital images superior to that of film-screen images.
CONCLUSION: Subjective visibility of normal anatomy of the hands and feet using selenium-based digital radiography was similar to that achieved using conventional film-screen radiography.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9888764     DOI: 10.2214/ajr.172.1.9888764

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.

Authors:  K Eklund; K Jonsson; G Lindblom; B Lundin; J Sanfridsson; M Sloth; B Sivberg
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

Review 2.  Digital radiography. A comparison with modern conventional imaging.

Authors:  G J Bansal
Journal:  Postgrad Med J       Date:  2006-07       Impact factor: 2.401

3.  Slot-scan digital radiography of the lower extremities: a comparison to computed radiography with respect to image quality and radiation dose.

Authors:  Kwang Hwi Lee; Jong Won Kwon; Young Cheol Yoon; Sang Hee Choi; Jee Young Jung; Ji Hye Kim; Sang Jun Lee
Journal:  Korean J Radiol       Date:  2009 Jan-Feb       Impact factor: 3.500

4.  The Application of Magnetic Resonance Imaging in Skeletal Age Assessment.

Authors:  Khalaf Alshamrani
Journal:  Appl Bionics Biomech       Date:  2022-02-21       Impact factor: 1.781

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.