Literature DB >> 9796892

Quantitative evaluation of a comprehensive motion, resolution, and attenuation correction program: initial experience.

P Rigo1, P Van Boxem, J Foulon, M Safi, J Engdahl, J Links.   

Abstract

BACKGROUND: Tomographic myocardial imaging is widely used in the diagnosis and evaluation of patients with coronary artery disease. However, its specificity remains suboptimal because of attenuation, resolution, and motion artifacts. The purpose of this study was to optimize and assess the value of attenuation, blur, and motion correction of myocardial single photon emission computed tomographic data. METHODS AND
RESULTS: Forty-seven studies were selected for analysis to provide 3 patient groups. Group A consisted of 18 patients with a low likelihood of coronary artery disease who were used to construct a quantitative normal database and assess changes in the normal bull's-eye produced by filtering and by attenuation correction. Group B consisted of 13 patients with a high probability of normal results, and group C consisted of 16 patients with coronary artery disease defined on angiography. The effects of attenuation correction, especially in conjunction with RESTORE (a depth-dependent deblurring filter), have been quantitated. Analysis indicates a trend to improved sensitivity and specificity for detecting individual vessel disease in this retrospective study. The motion correction program was successfully applied to 93% of patients but detected significant motion requiring correction in only 11 (24%) patients.
CONCLUSION: This preliminary retrospective study indicates a potential for improved myocardial single photon emission computed tomography imaging with the use of attenuation and motion correction together with a restorative deblurring filter. Confirmation by a multicenter study and larger patient numbers remain necessary to assess fully the prospective value of the technique.

Entities:  

Mesh:

Year:  1998        PMID: 9796892     DOI: 10.1016/s1071-3581(98)90176-3

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  19 in total

Review 1.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

2.  Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial.

Authors:  K F Van Train; J Maddahi; D S Berman; H Kiat; J Areeda; F Prigent; J Friedman
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

Review 3.  Quantitative myocardial perfusion single-photon emission computed tomographic imaging: quo vadis? (Where do we go from here?).

Authors:  E V Garcia
Journal:  J Nucl Cardiol       Date:  1994 Jan-Feb       Impact factor: 5.952

4.  Cardiac single-photon emission tomography: is attenuation correction enough?

Authors:  B F Hutton
Journal:  Eur J Nucl Med       Date:  1997-07

5.  Use of cross-correlation function to detect patient motion during SPECT imaging.

Authors:  R L Eisner; T Noever; D Nowak; W Carlson; D Dunn; J Oates; K Cloninger; H A Liberman; R E Patterson
Journal:  J Nucl Med       Date:  1987-01       Impact factor: 10.057

6.  Improved SPECT using simultaneous emission and transmission tomography.

Authors:  D L Bailey; B F Hutton; P J Walker
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

7.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease.

Authors:  E M Prvulovich; A H Lonn; J B Bomanji; P H Jarritt; P J Ell
Journal:  Eur J Nucl Med       Date:  1997-03

8.  Prediction of improvement of regional left ventricular function after surgical revascularization. A comparison of low-dose dobutamine echocardiography with 201Tl single-photon emission computed tomography.

Authors:  M Arnese; J H Cornel; A Salustri; A Maat; A Elhendy; A E Reijs; F J Ten Cate; D Keane; A H Balk; J R Roelandt
Journal:  Circulation       Date:  1995-06-01       Impact factor: 29.690

9.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

Authors:  E P Ficaro; J A Fessler; R J Ackermann; W L Rogers; J R Corbett; M Schwaiger
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

10.  Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.

Authors:  D J Fintel; J M Links; J A Brinker; T L Frank; M Parker; L C Becker
Journal:  J Am Coll Cardiol       Date:  1989-03-01       Impact factor: 24.094

View more
  10 in total

1.  Clinical significance of apical thinning after attenuation correction.

Authors:  Jonathan M Links; Lewis C Becker; Frank Anstett
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

2.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

3.  Use of MRI to assess the prediction of heart motion with gross body motion in myocardial perfusion imaging by stereotracking of markers on the body surface.

Authors:  Michael A King; Joyoni Dey; Karen Johnson; Paul Dasari; Joyeeta M Mukherjee; Joseph E McNamara; Arda Konik; Cliff Lindsay; Shaokuan Zheng; Dennis Coughlin
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 4.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

5.  Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT.

Authors:  Jonathan M Links; E Gordon DePuey; Raymond Taillefer; Lewis C Becker
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

6.  The influence of attenuation and scatter compensation on the apparent distribution of Tc-99m sestamibi in cardiac slices.

Authors:  P H Pretorius; M V Narayanan; S T Dahlberg; J A Leppo; M A King
Journal:  J Nucl Cardiol       Date:  2001 May-Jun       Impact factor: 5.952

7.  Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Authors:  Wassila Djaballah; Marc A Muller; Anne C Bertrand; Pierre Y Marie; Bernard Chalon; Karim Djaballah; Pierre Olivier; Andreï Codreanu; Gilles Karcher; Alain Bertrand
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

8.  Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial.

Authors:  J M Links; L C Becker; P Rigo; R Taillefer; L Hanelin; F Anstett; D Burckhardt; L Mixon
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

Review 9.  Attenuation correction for single photon emission computed tomography myocardial perfusion imaging.

Authors:  James R Corbett; James N Kritzman; Edward P Ficaro
Journal:  Curr Cardiol Rep       Date:  2004-01       Impact factor: 2.931

Review 10.  Review: comparison of PET rubidium-82 with conventional SPECT myocardial perfusion imaging.

Authors:  Adam A Ghotbi; Andreas Kjaer; Philip Hasbak
Journal:  Clin Physiol Funct Imaging       Date:  2013-09-13       Impact factor: 2.273

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.