Literature DB >> 6600755

Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections.

M Bergström, L Eriksson, C Bohm, G Blomqvist, J Litton.   

Abstract

A "deconvolution" algorithm for the determination of the scatter contribution in positron emission tomography is described. The projected distributions of scattered radiation measured with a line source at different positions in water phantoms are described analytically. It is shown that an integral transformation of the observed projections with a slightly modified analytical function gives an adequate description of the scattered radiation. The scatter distribution from any composite object can thus be calculated and subsequently subtracted. The algorithm is tested on different objects. The result shows that the level of scattered radiation can be reduced from 25 to 1% of the total count rate in the center of the projection from a homogeneous phantom.

Entities:  

Mesh:

Year:  1983        PMID: 6600755     DOI: 10.1097/00004728-198302000-00008

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  40 in total

1.  PET imaging with yttrium-86: comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction.

Authors:  H G Buchholz; H Herzog; G J Förster; H Reber; O Nickel; F Rösch; P Bartenstein
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-26       Impact factor: 9.236

2.  Towards PET imaging of intact pancreatic beta cell mass: a transgenic strategy.

Authors:  Rebecca McGirr; Shirley Hu; Siu-Pok Yee; Michael S Kovacs; Ting-Yim Lee; Savita Dhanvantari
Journal:  Mol Imaging Biol       Date:  2011-10       Impact factor: 3.488

3.  Improved positron emission tomography quantification by Fourier-based restoration filtering.

Authors:  J M Links; J P Leal; H W Mueller-Gaertner; H N Wagner
Journal:  Eur J Nucl Med       Date:  1992

4.  Frontal and temporal dopamine release during working memory and attention tasks in healthy humans: a positron emission tomography study using the high-affinity dopamine D2 receptor ligand [11C]FLB 457.

Authors:  Sargo Aalto; Anna Brück; Matti Laine; Kjell Någren; Juha O Rinne
Journal:  J Neurosci       Date:  2005-03-09       Impact factor: 6.167

5.  Assessment of the short-lived non-pure positron-emitting nuclide (120)I for PET imaging.

Authors:  H Herzog; S M Qaim; L Tellmann; S Spellerberg; D Kruecker; H H Coenen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-07-15       Impact factor: 9.236

6.  Realistic PET Monte Carlo Simulation With Pixelated Block Detectors, Light Sharing, Random Coincidences and Dead-Time Modeling.

Authors:  Bastein Guérin; Georges El Fakhri
Journal:  IEEE Trans Nucl Sci       Date:  2008       Impact factor: 1.679

7.  The effects of d-amphetamine on extrastriatal dopamine D2/D3 receptors: a randomized, double-blind, placebo-controlled PET study with [11C]FLB 457 in healthy subjects.

Authors:  Sargo Aalto; Jussi Hirvonen; Valtteri Kaasinen; Nora Hagelberg; Jaana Kajander; Kjell Någren; Timo Seppälä; Juha O Rinne; Harry Scheinin; Jarmo Hietala
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-11-05       Impact factor: 9.236

8.  An efficient method for correcting the edge artifact due to smoothing.

Authors:  J M Maisog; J Chmielowska
Journal:  Hum Brain Mapp       Date:  1998       Impact factor: 5.038

9.  Non-stationary spatial filtering and accelerated curve fitting for parametric imaging with dynamic PET.

Authors:  K Herholz
Journal:  Eur J Nucl Med       Date:  1988

10.  Quantification of radiotracer uptake with a dedicated breast PET imaging system.

Authors:  Raymond R Raylmana; Mark F Smith; Paul E Kinahan; Stan Majewski
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.