Literature DB >> 1311039

Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions.

K Søballe1, E S Hansen, H B-Rasmussen, P H Jørgensen, C Bünger.   

Abstract

Lack of initial mechanical stability of cementless prostheses may be responsible for fibrous tissue fixation of prosthetic components to bone. To study the influence of micromovements on bony ingrowth into titanium alloy (Ti) and hydroxyapatite (HA)-coated implants, a loaded unstable device producing movements of 500 microns during each gait cycle was developed. Mechanically stable implants served as controls. The implants were inserted into the weight-bearing regions of all four femoral condyles in each of seven mature dogs. Histological analysis after 4 weeks of implantation showed a fibrous tissue membrane surrounding both Ti and HA-coated implants subjected to micromovements, whereas variable amounts of bony ingrowth were obtained in mechanically stable implants. The pushout test showed that the shear strength of unstable Ti and HA implants was significantly reduced as compared with the corresponding mechanically stable implants (p less than 0.01). However, shear strength values of unstable HA-coated implants were significantly greater than those of unstable Ti implants (p less than 0.01) and comparable to those of stable Ti implants. The greatest shear strength was obtained with stable HA-coated implants, which was threefold stronger as compared with the stable Ti implants (p less than 0.001). Quantitative determination of bony ingrowth agreed with the mechanical test except for the stronger anchorage of unstable HA implants as compared with unstable Ti implants, where no difference in bony ingrowth was found. Unstable HA-coated implants were surrounded by a fibrous membrane containing islands of fibrocartilage with higher collagen concentration, whereas fibrous connective tissue with lower collagen concentration was predominant around unstable Ti implants. In conclusion, micromovements between bone and implant inhibited bony ingrowth and led to the development of a fibrous membrane. The presence of fibrocartilage and a higher collagen concentration in the fibrous membrane may be responsible for the increased shear strength of unstable HA implants. Mechanically stable implants with HA coating had the strongest anchorage and the greatest amount of bony ingrowth.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1311039     DOI: 10.1002/jor.1100100216

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  67 in total

1.  The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

Authors:  Kjeld Søballe; Olivier R G Mouzin; Louis A Kidder; Søren Overgaard; Joan E Bechtold
Journal:  Acta Orthop Scand       Date:  2003-06

2.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

3.  Bilayered calcium phosphate coating to promote osseointegration of a femoral stem prosthesis.

Authors:  E Goyenvalle; N J M Guyen; E Aguado; N Passuti; G Daculsi
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

4.  The dependence of osteoblastic response on variations in the chemical composition and physical properties of hydroxyapatite.

Authors:  S Best; B Sim; M Kayser; S Downes
Journal:  J Mater Sci Mater Med       Date:  1997-02       Impact factor: 3.896

5.  Cancellous bone osseointegration is enhanced by in vivo loading.

Authors:  Bettina M Willie; Xu Yang; Natalie H Kelly; Jane Han; Turya Nair; Timothy M Wright; Marjolein C H van der Meulen; Mathias P G Bostrom
Journal:  Tissue Eng Part C Methods       Date:  2010-05-22       Impact factor: 3.056

6.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

7.  Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

Authors:  M Viceconti; S Ricci; A Pancanti; A Cappello
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

8.  Effect of mechanical stimuli on skeletal regeneration around implants.

Authors:  Philipp Leucht; Jae-Beom Kim; Rima Wazen; Jennifer A Currey; Antonio Nanci; John B Brunski; Jill A Helms
Journal:  Bone       Date:  2006-12-18       Impact factor: 4.398

Review 9.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

Review 10.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.