Literature DB >> 15587465

Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

M Viceconti1, S Ricci, A Pancanti, A Cappello.   

Abstract

The objective of this research was to develop a purely biomechanical model, intended to predict the long-term secondary stability of the implant starting from the biomechanical stability immediately after the operation. A continuous rule-based adaptation scheme was formulated as a dynamic system, and the work verified if such a model produced unique and clinically meaningful solutions. It also investigated whether this continuous model provided results comparable with those of a simpler, discrete-states model used in a previous study. The proposed model showed stable convergence behaviour with all investigated initial conditions, with oscillatory behaviour limited to the first steps of the simulation. The results obtained with the wide range of initial conditions support the hypothesis of the existence and uniqueness of the solution for all initial conditions. The differences between the continuous model and the simpler and more efficient finite-states model were found to be extremely modest (less than 4% over the predicted bonded area). Because of these minimal differences, the use of the much faster finite-states model is recommended to investigate asymptotic conditions, and the continuous model described should be used to investigate the evolution over time of the adaptive process.

Mesh:

Year:  2004        PMID: 15587465     DOI: 10.1007/bf02345207

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  33 in total

1.  Cone prosthesis for the hip joint.

Authors:  H Wagner; M Wagner
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

Review 2.  Implant fixation by bone ingrowth.

Authors:  H Kienapfel; C Sprey; A Wilke; P Griss
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

3.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

4.  Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

Authors:  R M Pilliar; J M Lee; C Maniatopoulos
Journal:  Clin Orthop Relat Res       Date:  1986-07       Impact factor: 4.176

5.  Tissue reactions to titanium endoprostheses. Autopsy studies in four cases.

Authors:  F Lintner; K Zweymüller; G Brand
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

6.  In vivo femoral intramedullary pressure during uncemented hip arthroplasty.

Authors:  S Hofmann; R Hopf; G Mayr; G Schlag; M Salzer
Journal:  Clin Orthop Relat Res       Date:  1999-03       Impact factor: 4.176

7.  Push-out strength of hydroxyapatite coated by sputtering technique in bone.

Authors:  K Ozeki; T Yuhta; H Aoki; I Nishimura; Y Fukui
Journal:  Biomed Mater Eng       Date:  2001       Impact factor: 1.300

8.  Tensile bond between bone and titanium: a reappraisal of osseointegration.

Authors:  R Skripitz; P Aspenberg
Journal:  Acta Orthop Scand       Date:  1998-06

9.  Gap healing enhanced by hydroxyapatite coating in dogs.

Authors:  K Søballe; E S Hansen; H Brockstedt-Rasmussen; V E Hjortdal; G I Juhl; C M Pedersen; I Hvid; C Bünger
Journal:  Clin Orthop Relat Res       Date:  1991-11       Impact factor: 4.176

10.  Charnley low-friction arthroplasty of the hip. Long-term results.

Authors:  B M Wroblewski; P D Siney
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

View more