Literature DB >> 15125153

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

M Viceconti1, A Pancanti, M Dotti, F Traina, L Cristofolini.   

Abstract

A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

Entities:  

Mesh:

Year:  2004        PMID: 15125153     DOI: 10.1007/bf02344635

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  49 in total

1.  A proximal fixed anatomic femoral stem reduces stress shielding.

Authors:  T Niinimäki; J Junila; P Jalovaara
Journal:  Int Orthop       Date:  2001       Impact factor: 3.075

2.  Quantifying bone loss from the proximal femur after total hip arthroplasty.

Authors:  C K McCarthy; G G Steinberg; M Agren; D Leahey; E Wyman; D T Baran
Journal:  J Bone Joint Surg Br       Date:  1991-09

3.  Effect of porous coating and loading conditions on total hip femoral stem stability.

Authors:  F B Biegler; J D Reuben; T P Harrigan; F J Hou; J E Akin
Journal:  J Arthroplasty       Date:  1995-12       Impact factor: 4.757

4.  The Nicolas Andry award: comparative results of cemented and cementless total hip arthroplasty.

Authors:  C H Rorabeck; R B Bourne; B D Mulliken; N Nayak; A Laupacis; P Tugwell; D Feeney
Journal:  Clin Orthop Relat Res       Date:  1996-04       Impact factor: 4.176

5.  Tissue reactions to titanium endoprostheses. Autopsy studies in four cases.

Authors:  F Lintner; K Zweymüller; G Brand
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

6.  Radiographic assessment of cementless femoral components. Correlation with intraoperative mechanical stability.

Authors:  E J Vresilovic; W J Hozack; R H Rothman
Journal:  J Arthroplasty       Date:  1994-04       Impact factor: 4.757

7.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

8.  Retention of all-polyethylene acetabular components after femoral revision of a cemented total hip replacement.

Authors:  B R Hamlin; C Rowland; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  2001-11       Impact factor: 5.284

9.  Tensile bond between bone and titanium: a reappraisal of osseointegration.

Authors:  R Skripitz; P Aspenberg
Journal:  Acta Orthop Scand       Date:  1998-06

10.  The primary stability of a cementless stem varies between subjects as much as between activities.

Authors:  Alberto Pancanti; Marek Bernakiewicz; Marco Viceconti
Journal:  J Biomech       Date:  2003-06       Impact factor: 2.712

View more
  2 in total

1.  Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

Authors:  M Viceconti; S Ricci; A Pancanti; A Cappello
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

2.  No medium-term advantage of electrochemical deposition of hydroxyapatite in cementless femoral stems. 5-year RSA and DXA results from a randomized controlled trial.

Authors:  Bernhard Flatøy; Stephan M Röhrl; Berte Bøe; Lars Nordsletten
Journal:  Acta Orthop       Date:  2015-09-12       Impact factor: 3.717

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.