Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy.

Peter B Greer1, Carmen C Popescu.   

Abstract

Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s(-1) was found to be linear. A field size dependent response of up to 5% relative to dmax ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s(-1). The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12906179     DOI: 10.1118/1.1582469

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  47 in total

1.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.

Authors:  A J Vinall; A J Williams; V E Currie; A Van Esch; D Huyskens
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

2.  Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Dhanabalan Rajasekaran; Muniyappan Kannan; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

3.  Beam rate influence on dose distribution and fluence map in IMRT dynamic technique.

Authors:  Krzysztof Slosarek; Aleksandra Grządziel; Wojciech Osewski; Lukasz Dolla; Barbara Bekman; Borislava Petrovic
Journal:  Rep Pract Oncol Radiother       Date:  2012-02-10

4.  A study on dosimetric properties of electronic portal imaging device and its use as a quality assurance tool in Volumetric Modulated Arc Therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Prakash Jeevanandam; S A Syam Kumar; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2011-08-26

5.  Monte Carlo-based adaptive EPID dose kernel accounting for different field size responses of imagers.

Authors:  Song Wang; Joseph K Gardner; John J Gordon; Weidong Li; Luke Clews; Peter B Greer; Jeffrey V Siebers
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

6.  The Influence of Acquisition Mode on the Dosimetric Performance of an Amorphous Silicon Electronic Portal Imaging Device.

Authors:  Omemh Bawazeer; Sisira Herath; Siva Sarasanandarajah; Tomas Kron; Pradip Deb
Journal:  J Med Phys       Date:  2017 Apr-Jun

7.  Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements.

Authors:  Arpita Agarwal; Nikhil Rastogi; K J Maria Das; S A Yoganathan; D Udayakumar; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Apr-Jun

8.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

9.  Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy.

Authors:  Benjamin E Nelms; Karl H Rasmussen; Wolfgang A Tome
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

10.  Dosimetric properties and clinical application of an a-Si EPID for dynamic IMRT quality assurance.

Authors:  Kenji Matsumoto; Masahiko Okumura; Yoshiyuki Asai; Kouhei Shimomura; Masaya Tamura; Yasumasa Nishimura
Journal:  Radiol Phys Technol       Date:  2012-12-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.