Literature DB >> 24377007

Beam rate influence on dose distribution and fluence map in IMRT dynamic technique.

Krzysztof Slosarek1, Aleksandra Grządziel1, Wojciech Osewski1, Lukasz Dolla1, Barbara Bekman1, Borislava Petrovic2.   

Abstract

AIM: To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values.
BACKGROUND: Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques.
MATERIALS AND METHODS: Dose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software.
RESULTS: Dose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy.
CONCLUSION: Execution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.

Entities:  

Keywords:  Dose rate; Fluence map; Gamma index; IMRT

Year:  2012        PMID: 24377007      PMCID: PMC3863304          DOI: 10.1016/j.rpor.2012.01.004

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  19 in total

1.  Some limitations in the practical delivery of intensity modulated radiation therapy.

Authors:  J Meyer; J A Mills; O C Haas; E M Parvin; K J Burnham
Journal:  Br J Radiol       Date:  2000-08       Impact factor: 3.039

Review 2.  Intensity-modulated radiotherapy: current status and issues of interest.

Authors: 
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-11-15       Impact factor: 7.038

3.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

Authors:  M G Herman; J M Balter; D A Jaffray; K P McGee; P Munro; S Shalev; M Van Herk; J W Wong
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

4.  Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: implications for 4D radiotherapy.

Authors:  K Wijesooriya; C Bartee; J V Siebers; S S Vedam; P J Keall
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

5.  Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water.

Authors:  Antonella Fogliata; Giorgia Nicolini; Eugenio Vanetti; Alessandro Clivio; Luca Cozzi
Journal:  Phys Med Biol       Date:  2006-02-21       Impact factor: 3.609

6.  Relative dosimetry using active matrix flat-panel imager (AMFPI) technology.

Authors:  Y El-Mohri; L E Antonuk; J Yorkston; K W Jee; M Maolinbay; K L Lam; J H Siewerdsen
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

7.  Interactive use of on-line portal imaging in pelvic radiation.

Authors:  W De Neve; F Van den Heuvel; M Coghe; D Verellen; M De Beukeleer; A Roelstraete; P De Roover; L Thon; G Storme
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-02-15       Impact factor: 7.038

8.  Application of IMRT in adjuvant treatment of soft tissue sarcomas of the thigh-Preliminary results.

Authors:  Anna Sladowska; Marcin Hetnał; Paweł Dymek; Damian Kabat; Kamil Kisielewicz; Michał Wawrzak; Paweł Zawadzki; Jan Lesiak; Edward Byrski; Michał Waligórski
Journal:  Rep Pract Oncol Radiother       Date:  2011-04-08

9.  Potentials of on-line repositioning based on implanted fiducial markers and electronic portal imaging in prostate cancer radiotherapy.

Authors:  Reinhold Graf; Peter Wust; Volker Budach; Dirk Boehmer
Journal:  Radiat Oncol       Date:  2009-04-27       Impact factor: 3.481

10.  Impact of different leaf velocities and dose rates on the number of monitor units and the dose-volume-histograms using intensity modulated radiotherapy with sliding-window technique.

Authors:  Hilke Vorwerk; Daniela Wagner; Clemens F Hess
Journal:  Radiat Oncol       Date:  2008-09-23       Impact factor: 3.481

View more
  3 in total

1.  Treatment planning evaluation of sliding window and multiple static segments technique in intensity modulated radiotherapy.

Authors:  Khalid Iqbal; Muhammad Isa; Saeed Ahmad Buzdar; Kent Aallen Gifford; Muhammad Afzal
Journal:  Rep Pract Oncol Radiother       Date:  2012-12-21

2.  Clinical examples of 3D dose distribution reconstruction, based on the actual MLC leaves movement, for dynamic treatment techniques.

Authors:  Wojciech Osewski; Lukasz Dolla; Michał Radwan; Marta Szlag; Roman Rutkowski; Barbara Smolińska; Krzysztof Slosarek
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-17

3.  Impact of dose rate on accuracy of intensity modulated radiation therapy plan delivery using the pretreatment portal dosimetry quality assurance and setting up the workflow at hospital levels.

Authors:  Karunakaran Kaviarasu; N Arunai Nambi Raj; K Krishna Murthy; A Ananda Giri Babu; Bhaskar Laxman Durga Prasad
Journal:  J Med Phys       Date:  2015 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.