Literature DB >> 12714391

Variability across the optic nerve head in scanning laser tomography.

J C H Tan1, D F Garway-Heath, R A Hitchings.   

Abstract

AIM: To characterise measurement variability in scanning laser tomography of the optic nerve head.
METHODS: 21 normal and 21 glaucoma subjects underwent same and separate day test-retest Heidelberg retina tomograph imaging by the same and different operators.
RESULTS: Rim area was most reproducible among parameters. Its variability tended to be highest temporally and increased (p<0.05) with testing involving different operators and visits. Nature of regional variability differed between glaucoma and normal eyes and between standard and 320 micro m reference planes.
CONCLUSIONS: Rim area is reproducible and potentially useful as a marker of progression. Pattern of variability and the influence of different reference planes, disease, operators, and visits should be considered when evaluating progression.

Entities:  

Mesh:

Year:  2003        PMID: 12714391      PMCID: PMC1771663          DOI: 10.1136/bjo.87.5.557

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  16 in total

1.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

2.  Development of the standard reference plane for the Heidelberg retina tomograph.

Authors:  R O Burk; K Vihanninjoki; T Bartke; A Tuulonen; P J Airaksinen; H E Völcker; J M König
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-05       Impact factor: 3.117

3.  Long-term fluctuations of the normalised rim/disc area ratio quotient in normal eyes.

Authors:  C P Jonescu-Cuypers; G Thumann; R D Hilgers; K U Bartz-Schmidt; R Krott; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1999-03       Impact factor: 3.117

4.  Regional test-retest variability of confocal scanning laser tomography.

Authors:  L Brigatti; M Weitzman; J Caprioli
Journal:  Am J Ophthalmol       Date:  1995-10       Impact factor: 5.258

5.  Effect of the cardiac cycle on topographic measurements using confocal scanning laser tomography.

Authors:  B C Chauhan; T A McCormick
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-09       Impact factor: 3.117

6.  Test-retest variability of topographic measurements with confocal scanning laser tomography in patients with glaucoma and control subjects.

Authors:  B C Chauhan; R P LeBlanc; T A McCormick; J B Rogers
Journal:  Am J Ophthalmol       Date:  1994-07-15       Impact factor: 5.258

7.  Reproducibility of the optic nerve head topography with a new laser tomographic scanning device.

Authors:  K Rohrschneider; R O Burk; F E Kruse; H E Völcker
Journal:  Ophthalmology       Date:  1994-06       Impact factor: 12.079

8.  Initial glaucomatous optic disk and retinal nerve fiber layer abnormalities and their progression.

Authors:  A Tuulonen; P J Airaksinen
Journal:  Am J Ophthalmol       Date:  1991-04-15       Impact factor: 5.258

9.  Reproducibility of topographic parameters obtained with the heidelberg retina tomograph.

Authors:  F S Mikelberg; K Wijsman; M Schulzer
Journal:  J Glaucoma       Date:  1993       Impact factor: 2.503

10.  The mode of progressive disc cupping in ocular hypertension and glaucoma.

Authors:  J E Pederson; D R Anderson
Journal:  Arch Ophthalmol       Date:  1980-03
View more
  12 in total

1.  Glaucomatous progression in series of stereoscopic photographs and Heidelberg retina tomograph images.

Authors:  Neil O'Leary; David P Crabb; Steven L Mansberger; Brad Fortune; Michael D Twa; Michael J Lloyd; Aachal Kotecha; David F Garway-Heath; George A Cioffi; Chris A Johnson
Journal:  Arch Ophthalmol       Date:  2010-05

2.  Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements.

Authors:  N G Strouthidis; E T White; V M F Owen; T A Ho; D F Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

3.  [Structural diagnostics of course observation for glaucoma].

Authors:  C Y Mardin
Journal:  Ophthalmologe       Date:  2013-11       Impact factor: 1.059

4.  Comparison of measurement error of Cirrus HD-OCT and Heidelberg Retina Tomograph 3 in patients with early glaucomatous visual field defect.

Authors:  Alexander A Shpak; Maria K Sevostyanova; Svetlana N Ogorodnikova; Irina N Shormaz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-09-01       Impact factor: 3.117

Review 5.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

Review 6.  Assessment of rates of structural change in glaucoma using imaging technologies.

Authors:  K Mansouri; M T Leite; F A Medeiros; C K Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-07       Impact factor: 3.775

7.  Optic disc topographic parameters measured in the normal cynomolgus monkey by confocal scanning laser tomography.

Authors:  T Taniguchi; M Shimazawa; M Araie; G Tomita; M Sasaoka; Y Kitazawa; H Hara
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

8.  Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements.

Authors:  N G Strouthidis; E T White; V M F Owen; T A Ho; C J Hammond; D F Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

9.  Agreement in identification of glaucomatous progression between the optic disc photography and Heidelberg retina tomography in young glaucomatous patients.

Authors:  Paraskeva Hentova-Sencanic; Ivan Sencanic; Goran Trajković; Marija Bozic; Nevena Bjelovic
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

10.  Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets.

Authors:  Nicholas G Strouthidis; Hongli Yang; Brad Fortune; J Crawford Downs; Claude F Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-08-08       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.