Literature DB >> 19920494

Reproducibility of topographic parameters obtained with the heidelberg retina tomograph.

F S Mikelberg1, K Wijsman, M Schulzer.   

Abstract

The Heidelberg retina tomograph is a confocal scanning laser ophthalmoscope that permits recording of topographic information related to the optic nerve and retina. We studied the reproducibility of the topographic parameters obtained by recording five times sequentially the images obtained from one eye of five healthy people and five glaucoma patients. The reproducibility coefficients ranged from 60.5 to 99.4%. The results indicate that, for the parameters examined, the instrument has a high level of reproducibility.

Entities:  

Year:  1993        PMID: 19920494

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  18 in total

1.  Variability across the optic nerve head in scanning laser tomography.

Authors:  J C H Tan; D F Garway-Heath; R A Hitchings
Journal:  Br J Ophthalmol       Date:  2003-05       Impact factor: 4.638

2.  Comparison of long-term fluctuations: laser scanning tomography versus automated perimetry.

Authors:  Jens Funk; Heiko Mueller
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-08-29       Impact factor: 3.117

Review 3.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

4.  Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements.

Authors:  N G Strouthidis; E T White; V M F Owen; T A Ho; D F Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

5.  Detection and diagnosis of glaucoma: ocular imaging.

Authors:  Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-05-04       Impact factor: 4.799

6.  Variability of contour line alignment on sequential images with the Heidelberg Retina Tomograph.

Authors:  S Orgül; G A Croffi; E M Van Buskirk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-02       Impact factor: 3.117

7.  Effect of the cardiac cycle on topographic measurements using confocal scanning laser tomography.

Authors:  B C Chauhan; T A McCormick
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-09       Impact factor: 3.117

8.  Reproducibility of volumetric macular measurements in diabetic patients with the Heidelberg Retina Tomograph.

Authors:  H J Zambarakji; S A Vernon; A F Spencer; W M Amoaku
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 2.379

9.  Improved estimates of visual field progression using bayesian linear regression to integrate structural information in patients with ocular hypertension.

Authors:  Richard A Russell; Rizwan Malik; Balwantray C Chauhan; David P Crabb; David F Garway-Heath
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-05-14       Impact factor: 4.799

10.  Peripapillary atrophy in the unilateral exfoliation syndrome.

Authors:  Päivi Puska; Mika Harju; Ron Liebkind
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-01-28       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.