Literature DB >> 12706922

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.

Jürgen Pache1, Adnan Kastrati, Julinda Mehilli, Helmut Schühlen, Franz Dotzer, Jörg Hausleiter, Martin Fleckenstein, Franz Josef Neumann, Ulrich Sattelberger, Claus Schmitt, Martina Müller, Josef Dirschinger, Albert Schömig.   

Abstract

OBJECTIVES: We tested the hypothesis that thinner-strut stents are associated with a reduced rate of restenosis when comparing two stents with different design.
BACKGROUND: We have previously shown that, for two stents with similar design, the risk for restenosis is dependent on the strut thickness. It is unknown whether strut thickness preserves its relevance as a determinant of restenosis even in the presence of different stent designs.
METHODS: A total of 611 patients with symptomatic coronary artery disease were randomly assigned to receive either the thin-strut ACS RX Multilink stent (Guidant, Advanced Cardiovascular Systems, Santa Clara, California) (strut thickness 50 microm, interconnected ring design; n = 309) or the thick-strut BX Velocity stent (Cordis Corp., Miami, Florida) (strut thickness 140 microm, closed cell design; n = 302). The primary end point was angiographic restenosis (> or =50% diameter stenosis at follow-up angiography). Secondary end points were the incidence of target-vessel revascularization (TVR) and the combined rate of death and myocardial infarction (MI) at one year.
RESULTS: The incidence of angiographic restenosis was 17.9% in the thin-strut group and 31.4% in the thick-strut group, relative risk, 0.57 (95% confidence interval, 0.39 to 0.84), p < 0.001. A TVR due to restenosis was required in 12.3% of the thin-strut group and 21.9% of the thick-strut group, relative risk, 0.56 (95% confidence interval, 0.38 to 0.84), p = 0.002. No significant difference was observed in the combined incidence of death and MI at one year.
CONCLUSIONS: When two stents with different design are compared, the stent with thinner struts elicits less angiographic and clinical restenosis than the thicker-strut stent.

Entities:  

Mesh:

Year:  2003        PMID: 12706922     DOI: 10.1016/s0735-1097(03)00119-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  88 in total

1.  One-year clinical follow-up of a registry evaluating a percutaneous revascularisation strategy combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent.

Authors:  P R Stella; G Pavlakis; P Agostoni; H M Nathoe; S Hoseyni Guyomi; B J Hamer; T X Wildbergh; P A Doevendans; E Van Belle
Journal:  Neth Heart J       Date:  2010-10       Impact factor: 2.380

Review 2.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

3.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

Review 4.  Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques.

Authors:  Shann S Yu; Ryan A Ortega; Brendan W Reagan; John A McPherson; Hak-Joon Sung; Todd D Giorgio
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-08-10

5.  The influence of grain size on the ductility of micro-scale stainless steel stent struts.

Authors:  B P Murphy; H Cuddy; F J Harewood; T Connolley; P E McHugh
Journal:  J Mater Sci Mater Med       Date:  2006-01       Impact factor: 3.896

Review 6.  Coronary artery stents: identification and evaluation.

Authors:  J Butany; K Carmichael; S W Leong; M J Collins
Journal:  J Clin Pathol       Date:  2005-08       Impact factor: 3.411

Review 7.  Diagnostic and prognostic value of BMIPP imaging.

Authors:  Taishiro Chikamori; Akira Yamashina; Satoshi Hida; Tsunehiko Nishimura
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

8.  Coronary stenting: A matter of revascularization.

Authors:  Aldo Bonaventura; Fabrizio Montecucco; Luca Liberale
Journal:  World J Cardiol       Date:  2017-03-26

9.  Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis.

Authors:  Houman Zahedmanesh; Caitríona Lally
Journal:  Med Biol Eng Comput       Date:  2009-02-03       Impact factor: 2.602

10.  Comparison of near-wall hemodynamic parameters in stented artery models.

Authors:  Nandini Duraiswamy; Richard T Schoephoerster; James E Moore
Journal:  J Biomech Eng       Date:  2009-06       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.