Literature DB >> 16049279

Coronary artery stents: identification and evaluation.

J Butany1, K Carmichael, S W Leong, M J Collins.   

Abstract

First introduced in the 1980s, the coronary stent has been used to reduce the rate of arterial restenosis. Coronary stent implantation is currently a common procedure performed by interventional cardiologists, and the market for development and design is constantly expanding and evolving. This article was designed to assist pathologists in the accurate identification of coronary stents that are currently available, in addition to some that are no longer being implanted. The stents reviewed here were chosen based on frequency of use and/or occurrence in the literature. Some of the newer models have yet to undergo extensive clinical testing. The summaries accompanying each stent include concise physical descriptions and documented complications, intended to serve as a guide for the investigating pathologist.

Entities:  

Mesh:

Year:  2005        PMID: 16049279      PMCID: PMC1770873          DOI: 10.1136/jcp.2004.024174

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  43 in total

1.  Is provisional stenting the effective option? The WIDEST study (Wiktor stent in de novo stenosis). Widest Trial Investigators' Group.

Authors:  D S Fluck; P Chenu; P Mills; A Davies; J Street; E Paul; R Balcon; C A Layton
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

2.  Randomized comparison of GR-II stent and Palmaz-Schatz stent for elective treatment of coronary stenoses.

Authors:  A J Lansky; G S Roubin; C D O'Shaughnessy; P B Moore; L S Dean; A E Raizner; R D Safian; J P Zidar; J L Kerr; J J Popma; R Mehran; R E Kuntz; M B Leon
Journal:  Circulation       Date:  2000-09-19       Impact factor: 29.690

3.  Interventional cardiology in Europe 1999.

Authors:  Martin Rotter; Dorothy Pfiffner; Willibald Maier; Andreas M Zeiher; Bernhard Meier
Journal:  Eur Heart J       Date:  2003-06       Impact factor: 29.983

Review 4.  Recommendations on stent manufacture, implantation and utilization. Study Group of the Working Group on Coronary Circulation.

Authors:  R Balcon; R Beyar; S Chierchia; I De Scheerder; P G Hugenholtz; F Kiemeneij; B Meier; J Meyer; J P Monassier; W Wijns
Journal:  Eur Heart J       Date:  1997-10       Impact factor: 29.983

5.  Angiographic and clinical follow-up after coronary implantation of the ACS Multilink Duet stent: a single center experience.

Authors:  T Sayin; B Berkalp; O Akyürek; C Kervancioğlu; D Oral
Journal:  Jpn Heart J       Date:  2001-07

6.  Ten-year clinical and angiographic follow-up of coronary wallstent.

Authors:  D Carrié; M Elbaz; M Andrieu; P Cantié; J Fourcade; J Puel
Journal:  Am J Cardiol       Date:  2000-01-01       Impact factor: 2.778

7.  Six-month angiographic and 12-month clinical follow-up of MultiLink long (25 to 35 mm) stents for long coronary narrowings in patients with angina pectoris.

Authors:  John A Ormiston; Mark W I Webster; Peter N Ruygrok; Ian T Meredith; Justin P Ardill; Christopher E Buller; Donald R Ricci; Charles Chan; Gerard P Devlin; James T Stewart; Ian M Penn; Sue Price; Bruce Webber; Teena West
Journal:  Am J Cardiol       Date:  2002-08-01       Impact factor: 2.778

Review 8.  Sirolimus-eluting coronary stents: novel devices for the management of coronary artery disease.

Authors:  Angela Cheng-Lai; William H Frishman
Journal:  Am J Ther       Date:  2004 May-Jun       Impact factor: 2.688

9.  Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty.

Authors:  U Sigwart; J Puel; V Mirkovitch; F Joffre; L Kappenberger
Journal:  N Engl J Med       Date:  1987-03-19       Impact factor: 91.245

Review 10.  Collagens, integrins, and the discoidin domain receptors in arterial occlusive disease.

Authors:  Christopher D Franco; Guangpei Hou; Michelle P Bendeck
Journal:  Trends Cardiovasc Med       Date:  2002-05       Impact factor: 6.677

View more
  7 in total

1.  Photoacoustic imaging of clinical metal needles in tissue.

Authors:  Jimmy Su; Andrei Karpiouk; Bo Wang; Stanislav Emelianov
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Management of embedded metallic stents used in the treatment of grades III and IV subglottic, and upper tracheal stenosis in adults.

Authors:  Khalil Sendi; Talal Al-Khatib; Duha G Ahmed; Al-Baraa Tonkul
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-04-29       Impact factor: 2.503

3.  Quantitative biocompatibility evaluation of nickel-free high-nitrogen stainless steel in vitro/in vivo.

Authors:  Motoki Inoue; Makoto Sasaki; Yasuyuki Katada; Tetsushi Taguchi
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-07-13       Impact factor: 3.368

Review 4.  Coronary Stents: History, Design, and Construction.

Authors:  Torrey Schmidt; J Dawn Abbott
Journal:  J Clin Med       Date:  2018-05-29       Impact factor: 4.241

5.  Tissue-engineered blood vessel mimics in complex geometries for intravascular device testing.

Authors:  Robert Dalton Chavez; Sara Leifer Walls; Kristen O'Halloran Cardinal
Journal:  PLoS One       Date:  2019-06-26       Impact factor: 3.240

6.  First-in-Human Evaluation of the Safety and Efficacy of a Novel Stent Positioning Assistance System for Precise Positioning of Coronary Stents.

Authors:  Elias Hellou; Michael Jonas; Danny Dvir
Journal:  J Interv Cardiol       Date:  2022-03-27       Impact factor: 2.279

7.  Electrochemical Polymerization of PEDOT-Graphene Oxide-Heparin Composite Coating for Anti-fouling and Anti-clotting of Cardiovascular Stents.

Authors:  Ming-Chien Yang; Hui-Ming Tsou; Yu-Sheng Hsiao; Yu-Wei Cheng; Che-Chun Liu; Li-Ying Huang; Xin-Yao Peng; Ting-Yu Liu; Ming-Chi Yung; Chuan-Chih Hsu
Journal:  Polymers (Basel)       Date:  2019-09-18       Impact factor: 4.329

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.