Literature DB >> 19189146

Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis.

Houman Zahedmanesh1, Caitríona Lally.   

Abstract

Many clinical studies, including the ISAR-STEREO trial, have identified stent strut thickness as an independent predictor of in-stent restenosis where thinner struts result in lower restenosis than thicker struts. The aim of this study was to more conclusively identify the mechanical stimulus for in-stent restenosis using results from such clinical trials as the ISAR-STEREO trial. The mechanical environment in arteries stented with thin and thicker strut stents was investigated using numerical modelling techniques. Finite element models of the stents used in the ISAR-STEREO clinical trial were developed and the stents were deployed in idealized stenosed vessel geometries in order to compare the mechanical environment of the vessel for each stent. The stresses induced within the stented vessels by these stents were compared to determine the level of vascular injury caused to the artery by the stents with different strut thickness. The study found that when both stents were expanded to achieve the same initial maximum stent diameter that the thinner strut stent recoiled to a greater extent resulting in lower luminal gain but also lower stresses in the vessel wall, which is hypothesised to be responsible for the lower restenosis outcome. This study supports the hypothesis that arteries develop restenosis in response to injury, where high vessel stresses are a good measure of that injury. This study points to a critical stress level in arteries, above which an aggressive healing response leads to in-stent restenosis in stented vessels. Stents can be designed to reduce stresses in this range in arteries using preclinical tools such as numerical modelling.

Entities:  

Mesh:

Year:  2009        PMID: 19189146     DOI: 10.1007/s11517-009-0432-5

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  23 in total

Review 1.  Stent design: implications for restenosis.

Authors:  Dougal R McLean; Neal L Eiger
Journal:  Rev Cardiovasc Med       Date:  2002       Impact factor: 2.930

2.  In-stent restenosis in small coronary arteries: impact of strut thickness.

Authors:  Carlo Briguori; Cristiano Sarais; Paolo Pagnotta; Francesco Liistro; Matteo Montorfano; Alaide Chieffo; Fabio Sgura; Nicola Corvaja; Remo Albiero; Goran Stankovic; Costantinos Toutoutzas; Erminio Bonizzoni; Carlo Di Mario; Antonio Colombo
Journal:  J Am Coll Cardiol       Date:  2002-08-07       Impact factor: 24.094

3.  Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen.

Authors:  P H Grewe; T Deneke; A Machraoui; J Barmeyer; K M Müller
Journal:  J Am Coll Cardiol       Date:  2000-01       Impact factor: 24.094

4.  Cyclic strain inhibits Notch receptor signaling in vascular smooth muscle cells in vitro.

Authors:  David Morrow; Catherine Sweeney; Yvonne A Birney; Philip M Cummins; Dermot Walls; Eileen M Redmond; Paul A Cahill
Journal:  Circ Res       Date:  2005-02-10       Impact factor: 17.367

5.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

Authors:  Gerhard A Holzapfel; Michael Stadler; Thomas C Gasser
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

Review 6.  Role of stent design and coatings on restenosis and thrombosis.

Authors:  Hidehiko Hara; Masato Nakamura; Julio C Palmaz; Robert S Schwartz
Journal:  Adv Drug Deliv Rev       Date:  2006-03-06       Impact factor: 15.470

7.  Effects of stent design parameters on normal artery wall mechanics.

Authors:  Julian Bedoya; Clark A Meyer; Lucas H Timmins; Michael R Moreno; James E Moore
Journal:  J Biomech Eng       Date:  2006-10       Impact factor: 2.097

8.  Changes in wall mechanics after endovascular stenting in the rabbit aorta: comparison of three stent designs.

Authors:  H Vernhet; R Demaria; J M Juan; M C Oliva-Lauraire; J P Sénac; M Dauzat
Journal:  AJR Am J Roentgenol       Date:  2001-03       Impact factor: 3.959

9.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

Authors:  D L Fischman; M B Leon; D S Baim; R A Schatz; M P Savage; I Penn; K Detre; L Veltri; D Ricci; M Nobuyoshi
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

10.  Stented artery biomechanics and device design optimization.

Authors:  Lucas H Timmins; Michael R Moreno; Clark A Meyer; John C Criscione; Alexander Rachev; James E Moore
Journal:  Med Biol Eng Comput       Date:  2007-03-21       Impact factor: 3.079

View more
  12 in total

1.  An in silico study on the role of smooth muscle cell migration in neointimal formation after coronary stenting.

Authors:  Hannan Tahir; Ioana Niculescu; Carles Bona-Casas; Roeland M H Merks; Alfons G Hoekstra
Journal:  J R Soc Interface       Date:  2015-07-06       Impact factor: 4.118

2.  Effects of endothelium, stent design and deployment on the nitric oxide transport in stented artery: a potential role in stent restenosis and thrombosis.

Authors:  Xiao Liu; Min Wang; Nan Zhang; Zhanming Fan; Yubo Fan; Xiaoyan Deng
Journal:  Med Biol Eng Comput       Date:  2015-02-26       Impact factor: 2.602

3.  CCN4 regulates vascular smooth muscle cell migration and proliferation.

Authors:  Hao Liu; Wenpeng Dong; Zhiqi Lin; Jingbo Lu; Heng Wan; Zhongxin Zhou; Zhengjun Liu
Journal:  Mol Cells       Date:  2013-06-25       Impact factor: 5.034

4.  A nonlinear finite element simulation of balloon expandable stent for assessment of plaque vulnerability inside a stenotic artery.

Authors:  Alireza Karimi; Mahdi Navidbakhsh; Hiroshi Yamada; Reza Razaghi
Journal:  Med Biol Eng Comput       Date:  2014-06-03       Impact factor: 2.602

5.  Numerical Simulation of Stent Angioplasty with Predilation: An Investigation into Lesion Constitutive Representation and Calcification Influence.

Authors:  C Conway; J P McGarry; E R Edelman; P E McHugh
Journal:  Ann Biomed Eng       Date:  2017-05-09       Impact factor: 3.934

6.  Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design.

Authors:  Hannan Tahir; Alfons G Hoekstra; Eric Lorenz; Patricia V Lawford; D Rodney Hose; Julian Gunn; David J W Evans
Journal:  Interface Focus       Date:  2011-03-30       Impact factor: 3.906

7.  Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty.

Authors:  Thuy Pham; Milton Deherrera; Wei Sun
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-02-13       Impact factor: 1.763

8.  On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests.

Authors:  Markus A Geith; Krzysztof Swidergal; Bernd Hochholdinger; Thomas G Schratzenstaller; Marcus Wagner; Gerhard A Holzapfel
Journal:  Int J Numer Method Biomed Eng       Date:  2019-11       Impact factor: 2.648

9.  Stenting-induced Vasa Vasorum compression and subsequent flow resistance: a finite element study.

Authors:  Andrea Corti; Annalisa De Paolis; John Tarbell; Luis Cardoso
Journal:  Biomech Model Mechanobiol       Date:  2020-08-04

10.  Waves and fluid-solid interaction in stented blood vessels.

Authors:  S Frecentese; L P Argani; A B Movchan; N V Movchan; G Carta; M L Wall
Journal:  Proc Math Phys Eng Sci       Date:  2018-01-17       Impact factor: 2.704

View more