Evaluation of a new advanced thoracic bioimpedance device for estimation of cardiac output.

D G Haryadi1, D R Westenskow, L A Critchley, S I Schookin, V G Zubenko, K R Beliaev, A A Morozov.   

Abstract

OBJECTIVE: This study is an evaluation of a new thoracic bioimpedance cardiac output monitoring system which incorporates a modified form of the Kubicek equation and a method of estimating the left ventricular ejection time from the time derivative bioimpedance signals.
METHODS: The performance of the new system was compared with conventional thermodilution in a porcine model. One hundred and ninety nine (n = 199) paired measurements of thermodilution cardiac output (TDCO) (range 1.20-18.00 L/min) and thoracic bioimpedance cardiac output (BICO) were collected in 7 pigs. The bioimpedance measurements were adjusted for the animal's weight and chest circumference, thus compensating for the differences in the anatomy of pigs when compared to humans. Data were compared using weighted correlation coefficient and Bland-Altman analysis.
RESULTS: The weighted correlation coefficient between TDCO and BICO values was 0.87 (n = 199). The Bland-Altman technique yielded a precision of the device of +/-1.69 L/min with a bias of 0.11 L/min.
CONCLUSION: The results from the porcine study show that the new system performed well over a wide range of cardiac outputs, comparing favorably with data from other new bioimpedance cardiac output devices currently available in the market.

Entities:  

Mesh:

Year:  1999        PMID: 12578087     DOI: 10.1023/a:1009925220299

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  24 in total

1.  Abdominal surgery alters the calibration of bioimpedance cardiac output measurement.

Authors:  L A Critchley; D H Leung; T G Short
Journal:  Int J Clin Monit Comput       Date:  1996-02

2.  Wet lungs and impedance cardiography.

Authors:  L A Critchley; J A Critchley
Journal:  Anaesth Intensive Care       Date:  1997-06       Impact factor: 1.669

3.  Electrical bioimpedance for noninvasive measurement of cardiac output.

Authors:  M H Weil
Journal:  Crit Care Med       Date:  1997-09       Impact factor: 7.598

4.  New signal processing techniques for improved precision of noninvasive impedance cardiography.

Authors:  J H Nagel; L Y Shyu; S P Reddy; B E Hurwitz; P M McCabe; N Schneiderman
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Calculating correlation coefficients with repeated observations: Part 2--Correlation between subjects.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1995-03-11

7.  Calculating correlation coefficients with repeated observations: Part 1--Correlation within subjects.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1995-02-18

8.  Comparison of bioimpedance and thermodilution methods for determining cardiac output: experimental and clinical studies.

Authors:  F G Spinale; H D Reines; F A Crawford
Journal:  Ann Thorac Surg       Date:  1988-04       Impact factor: 4.330

9.  Continuous noninvasive estimation of cardiac output by electrical bioimpedance: an experimental study in dogs.

Authors:  K K Tremper; S M Hufstedler; S J Barker; J Zaccari; D Harris; S Anderson; V Roohk
Journal:  Crit Care Med       Date:  1986-03       Impact factor: 7.598

10.  Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation.

Authors:  W C Shoemaker; C C Wo; M H Bishop; P L Appel; J M Van de Water; G R Harrington; X Wang; R S Patil
Journal:  Crit Care Med       Date:  1994-12       Impact factor: 7.598

View more
  4 in total

1.  Averaging improves the quality of impedance stroke volume measurements during the head up tilt test.

Authors:  Ye Zhang; Lester A H Critchley; Julian A J H Critchley
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

2.  Evaluation of impedance based indices of cardiac contractility in dogs.

Authors:  Zhi-yong Peng; Lester A H Critchley; Benny S P Fok; Anthony E James
Journal:  J Clin Monit Comput       Date:  2004-04       Impact factor: 2.502

3.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

4.  A comparison of two impedance cardiographs using head-up tilting and trend analysis.

Authors:  Lester A H Critchley; Ye Zhang; Julian A J H Critchley; Raymond C K Chung
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.