Continuous noninvasive estimation of cardiac output by electrical bioimpedance: an experimental study in dogs.

K K Tremper, S M Hufstedler, S J Barker, J Zaccari, D Harris, S Anderson, V Roohk.   

Abstract

A new device has been developed to estimate continuously and noninvasively cardiac output from the thoracic electrical bioimpedance (CObi). CObi was compared to cardiac output by thermodilution (COtd) in five anesthetized dogs. Blood pressure, blood volume, and blood flow were manipulated by hemorrhage and infusions of sodium nitroprusside and phenylephrine. These data were used to determine the correlation between CObi and COtd under conditions of hypotensive normal flow and normotensive low flow, as well as during hemorrhagic shock and resuscitation. The CObi device was calibrated in vivo to COtd for each dog at the beginning of each experiment. CObi had a significant positive correlation with COtd throughout the experiments (r = 0.84, slope = 0.91, intercept = 0.55, p less than 0.01), and CObi predicted COtd with a standard error of the estimate of 0.81 L/min. Neither heart rate nor mean arterial pressure was significantly correlated with COtd or CObi. During severe hemorrhagic shock, CObi could not determine cardiac output in two of the dogs when COtd averaged 1.7 L/min. These data indicate that CObi is a blood-flow related variable that can be monitored continuously.

Entities:  

Mesh:

Year:  1986        PMID: 3943340     DOI: 10.1097/00003246-198603000-00013

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

1.  Evaluation of a new advanced thoracic bioimpedance device for estimation of cardiac output.

Authors:  D G Haryadi; D R Westenskow; L A Critchley; S I Schookin; V G Zubenko; K R Beliaev; A A Morozov
Journal:  J Clin Monit Comput       Date:  1999-02       Impact factor: 2.502

2.  Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.

Authors:  J C Preiser; A Daper; J N Parquier; B Contempré; J L Vincent
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

Review 3.  Non-invasive methods of measuring cardiac output.

Authors:  G J Dobb; K D Donovan
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

4.  A comparison of two impedance cardiographs using head-up tilting and trend analysis.

Authors:  Lester A H Critchley; Ye Zhang; Julian A J H Critchley; Raymond C K Chung
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502