Literature DB >> 12578034

Partial CO2 rebreathing cardiac output--operating principles of the NICO system.

M B Jaffe1.   

Abstract

The partial rebreathing method of cardiac output estimation is reviewed with a particular focus on its application for continuous monitoring, rebreathing and implementations and from both a historical and technical perspective. The assumptions of the method are discussed as well as the various implementations. The NICO monitor and rebreathing valve are described from a functional view. The clinical data including (a) comparisons between bolus thermodilution and continuous thermodilution in patients in the OR setting, (b) comparisons to continuous thermodilution with both the Baxter and Abbott continuous cardiac output devices and (c) comparison between different means of shunt correction are presented. Compared to conventional cardiac output methods, the partial CO2 rebreathing technique is non-invasive, can easily be automated and can provide real-time and continuous cardiac output monitoring. Taking advantage of modern sophisticated sensor and signal processing technology and integrating multiple monitored physiological variables the NICO monitor is the first commercially available cardiac output system making use of the partial rebreathing of CO2.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 12578034     DOI: 10.1023/a:1009981313076

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  13 in total

1.  Noninvasive measurement of cardiac output using partial CO2 rebreathing.

Authors:  J M Capek; R J Roy
Journal:  IEEE Trans Biomed Eng       Date:  1988-09       Impact factor: 4.538

2.  Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow.

Authors:  M G de Abreu; M Quintel; M Ragaller; D M Albrecht
Journal:  Crit Care Med       Date:  1997-04       Impact factor: 7.598

3.  A new method of using gas exchange measurements for the noninvasive determination of cardiac output: clinical experiences in adults following cardiac surgery.

Authors:  B Osterlund; A Gedeon; P Krill; G Johansson; S Reiz
Journal:  Acta Anaesthesiol Scand       Date:  1995-08       Impact factor: 2.105

4.  Noninvasive pulmonary blood flow for optimal PEEP.

Authors:  A Gedeon
Journal:  Clin Physiol       Date:  1985

5.  Reliability of the thermodilution method in the determination of cardiac output in clinical practice.

Authors:  C W Stetz; R G Miller; G E Kelly; T A Raffin
Journal:  Am Rev Respir Dis       Date:  1982-12

6.  Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.

Authors:  D G Haryadi; J A Orr; K Kuck; S McJames; D R Westenskow
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

7.  The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators.

Authors:  A F Connors; T Speroff; N V Dawson; C Thomas; F E Harrell; D Wagner; N Desbiens; L Goldman; A W Wu; R M Califf; W J Fulkerson; H Vidaillet; S Broste; P Bellamy; J Lynn; W A Knaus
Journal:  JAMA       Date:  1996-09-18       Impact factor: 56.272

8.  Noninvasive cardiac output determined with a new method based on gas exchange measurements and carbon dioxide rebreathing: a study in animals/pigs.

Authors:  A Gedeon; P Krill; J Kristensen; I Gottlieb
Journal:  J Clin Monit       Date:  1992-10

9.  The PIO2 vs. SpO2 diagram: a non-invasive measure of pulmonary oxygen exchange.

Authors:  D J Sapsford; J G Jones
Journal:  Eur J Anaesthesiol       Date:  1995-07       Impact factor: 4.330

10.  Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass.

Authors:  T W Latson; C W Whitten; D O'Flaherty
Journal:  Anesthesiology       Date:  1993-12       Impact factor: 7.892

View more
  13 in total

1.  Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?

Authors:  Naka Imakiire; Takeshi Omae; Akira Matsunaga; Ryuzo Sakata; Yuichi Kanmura
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

2.  Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO(2) Fick method.

Authors:  Philip J Peyton; Daniel Thompson; Paul Junor
Journal:  J Clin Monit Comput       Date:  2008-07-12       Impact factor: 2.502

3.  Non-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique.

Authors:  Alessia Mattei; Emiliano Schena; Stefano Cecchini; Paola Proscia; Paola Saccomandi; Sergio Silvestri; Massimiliano Carassiti
Journal:  J Clin Monit Comput       Date:  2014-02-22       Impact factor: 2.502

4.  Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.

Authors:  Lara Brewer; Joseph Orr; Earl Fulcher; Boaz Markewitz
Journal:  J Clin Monit Comput       Date:  2011-11-06       Impact factor: 2.502

5.  Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.

Authors:  D G Haryadi; J A Orr; K Kuck; S McJames; D R Westenskow
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

6.  A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation.

Authors:  Monica Rocco; Gustavo Spadetta; Andrea Morelli; Donatella Dell'Utri; Patrizia Porzi; Giorgio Conti; Paolo Pietropaoli
Journal:  Intensive Care Med       Date:  2003-12-03       Impact factor: 17.440

7.  [Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].

Authors:  J Reutershan; T Kapp; K Unertl; R Fretschner
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

8.  Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method.

Authors:  Andras Gedeon; Paul Krill; Barbro Osterlund
Journal:  J Clin Monit Comput       Date:  2002-07       Impact factor: 2.502

Review 9.  Advances in monitoring and management of shock.

Authors:  Haifa Mtaweh; Erin V Trakas; Erik Su; Joseph A Carcillo; Rajesh K Aneja
Journal:  Pediatr Clin North Am       Date:  2013-03-29       Impact factor: 3.278

10.  Improved accuracy of cardiac output estimation by the partial CO2 rebreathing method.

Authors:  Yoshifumi Kotake; Takashige Yamada; Hiromasa Nagata; Takeshi Suzuki; Ryohei Serita; Nobuyuki Katori; Junzo Takeda; Hideyuki Shimizu
Journal:  J Clin Monit Comput       Date:  2009-03-20       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.