Literature DB >> 7588667

The PIO2 vs. SpO2 diagram: a non-invasive measure of pulmonary oxygen exchange.

D J Sapsford1, J G Jones.   

Abstract

A non-invasive method for measuring pulmonary oxygen exchange is described using a plot of inspired oxygen partial pressure (PIO2) vs. oxygen saturation (SpO2). This method was assessed using nine normal subjects and 35 patients undergoing major surgery, including five thoracotomies. In each patient PIO2 was varied to produce a range of values of SpO2 between 85% and 99%. A model based on the inspired to arterial oxygen difference involving the shunt equation, solved by simultaneous numerical methods, was used to show how the PIO2 vs. SaO2 relationship could be used to derive two parameters of oxygen exchange, the PIO2-Pco2 difference and the Virtual Shunt. The model allows the inspired to arterial difference in PO2 to be divided into (a) an inspired to 'ideal' alveolar difference attributable to the balance between alveolar ventilation and oxygen uptake; (b) an 'ideal' alveolar to end-capillary difference attributable to inhomogeneity in ventilation/perfusion ratios; and (c) end-capillary to arterial difference attributable to true shunt, which was termed 'virtual shunt' because of the uncertainties of assuming fixed values for haemoglobin concentration and arteriovenous oxygen content difference. The coefficient of determination showed that there was a good fit of the model to the data. Because the method is model-based it enables extrapolation to different PIO2 values as well as the study of the evolution of changes in gas exchange under varying conditions.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7588667

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  13 in total

1.  Non-invasive assessment of shunt and ventilation/perfusion ratio in neonates with pulmonary failure.

Authors:  H L Smith; J G Jones
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-09       Impact factor: 5.747

2.  Partial CO2 rebreathing cardiac output--operating principles of the NICO system.

Authors:  M B Jaffe
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

3.  Non-invasive measurement of reduced ventilation:perfusion ratio and shunt in infants with bronchopulmonary dysplasia: a physiological definition of the disease.

Authors:  D Quine; C M Wong; E M Boyle; J G Jones; B J Stenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-06-23       Impact factor: 5.747

4.  Can new pulmonary gas exchange parameters contribute to evaluation of pulmonary congestion in left-sided heart failure?

Authors:  J Moesgaard; J Hedegaard Kristensen; J Malczynski; C Holst-Hansen; S Edward Rees; D Murley; S Andreassen; J Brondum Frokjaer; E Toft
Journal:  Can J Cardiol       Date:  2009-03       Impact factor: 5.223

5.  Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch.

Authors:  Geoffrey G Lockwood; Nick L S Fung; J Gareth Jones
Journal:  J Clin Monit Comput       Date:  2014-01-09       Impact factor: 2.502

Review 6.  Journal of clinical monitoring and computing 2014 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-03-04       Impact factor: 2.502

7.  Near-real-time pulmonary shunt and dead space measurement with micropore membrane inlet mass spectrometry in pigs with induced pulmonary embolism or acute lung failure.

Authors:  D Gerber; R Vasireddy; B Varadarajan; V Hartwich; M Y Schär; B Eberle; A Vogt
Journal:  J Clin Monit Comput       Date:  2019-01-02       Impact factor: 2.502

8.  Toxicodynamics of rigid polystyrene microparticles on pulmonary gas exchange in mice: implications for microemboli-based drug delivery systems.

Authors:  H L Kutscher; D Gao; S Li; C B Massa; J Cervelli; M Deshmukh; L B Joseph; D L Laskin; P J Sinko
Journal:  Toxicol Appl Pharmacol       Date:  2012-11-08       Impact factor: 4.219

9.  The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10-15 minutes.

Authors:  Stephen Edward Rees; Søren Kjaergaard; Per Perthorgaard; Jerzy Malczynski; Egon Toft; Steen Andreassen
Journal:  J Clin Monit Comput       Date:  2002-01       Impact factor: 2.502

10.  Non-invasive estimation of shunt and ventilation-perfusion mismatch.

Authors:  Søren Kjaergaard; Stephen Rees; Jerzy Malczynski; Jørgen Ahrenkiel Nielsen; Per Thorgaard; Egon Toft; Steen Andreassen
Journal:  Intensive Care Med       Date:  2003-04-16       Impact factor: 17.440

View more