Literature DB >> 3139547

Noninvasive measurement of cardiac output using partial CO2 rebreathing.

J M Capek, R J Roy.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3139547     DOI: 10.1109/10.7266

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  22 in total

1.  Partial CO2 rebreathing cardiac output--operating principles of the NICO system.

Authors:  M B Jaffe
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

2.  Development and in vitro validation of a device for measuring non-shunt cardiac output by nitrous oxide throughflow.

Authors:  G M Vartuli; R B Burfoot; G J B Robinson; P J Peyton; P A Junor
Journal:  Med Biol Eng Comput       Date:  2002-07       Impact factor: 2.602

3.  Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography.

Authors:  Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2012-02-18       Impact factor: 2.502

4.  Capnodynamic assessment of effective lung volume during cardiac output manipulations in a porcine model.

Authors:  Caroline Hällsjö Sander; Per-Arne Lönnqvist; Magnus Hallbäck; Fernando Suarez Sipmann; Mats Wallin; Anders Oldner; Håkan Björne
Journal:  J Clin Monit Comput       Date:  2015-09-16       Impact factor: 2.502

Review 5.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

6.  Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO(2) Fick method.

Authors:  Philip J Peyton; Daniel Thompson; Paul Junor
Journal:  J Clin Monit Comput       Date:  2008-07-12       Impact factor: 2.502

Review 7.  Clinical use of volumetric capnography in mechanically ventilated patients.

Authors:  Peter Kremeier; Stephan H Böhm; Gerardo Tusman
Journal:  J Clin Monit Comput       Date:  2019-05-31       Impact factor: 2.502

8.  [Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations].

Authors:  M Bock; T Sturm; J Motsch
Journal:  Anaesthesist       Date:  2007-07       Impact factor: 1.041

9.  A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation.

Authors:  Monica Rocco; Gustavo Spadetta; Andrea Morelli; Donatella Dell'Utri; Patrizia Porzi; Giorgio Conti; Paolo Pietropaoli
Journal:  Intensive Care Med       Date:  2003-12-03       Impact factor: 17.440

10.  Non-invasive pulmonary blood flow measurement by means of CO2 analysis of expiratory gases.

Authors:  R J Bosman; C P Stoutenbeek; D F Zandstra
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.