Literature DB >> 12548450

Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation.

Jean-Yves Jenny1, Cyril Boeri.   

Abstract

The accuracy of implantation is an accepted prognostic factor for the long-term survival of unicompartmental knee prostheses (UKP). We developed a non-image-guided navigation system for UKP implantation without any extramedullary or intramedullary guiding device. The 30 patients operated on with the navigation system (group A) were matched to 30 patients operated on with the conventional technique (group B) using age, sex, body mass index, preoperative coronal mechanical femorotibial angle, and severity of the preoperative degenerative changes. All patients had a complete radiological examination in the first 3 months after the index procedure, with anteroposterior and lateral plain knee radiographs and anteroposterior and lateral long leg radiographs. Coronal femorotibial mechanical angle and both coronal and sagittal orientations of the femoral and tibial components were measured. There were no significant differences in the mean numerical values of all measured angles except for the sagittal orientation of the tibial component, with a significant excessive posterior tibial slope in group B. There was a significant increase in the rate of prostheses implanted in the desired angular range for all criteria except the coronal mechanical femorotibial angle in group A. An optimal implantation with all optimal items was obtained by 18 cases in group A and 6 cases in group B. Navigated implantation of a UKP with the used, non-image-based system improved the accuracy of the radiological implantation without any significant inconvenience and with little change in the conventional operative technique. The only inconvenience was a 20-min longer operative time. This improvement could be related to a longer survival of such implanted prostheses.

Entities:  

Mesh:

Year:  2002        PMID: 12548450     DOI: 10.1007/s00167-002-0333-8

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  16 in total

1.  Unicompartmental or total knee replacement? Five-year results of a prospective, randomised trial of 102 osteoarthritic knees with unicompartmental arthritis.

Authors:  J H Newman; C E Ackroyd; N A Shah
Journal:  J Bone Joint Surg Br       Date:  1998-09

2.  Computer assisted knee replacement.

Authors:  S L Delp; S D Stulberg; B Davies; F Picard; F Leitner
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

3.  10-year survivorship of metal-backed, unicompartmental arthroplasty.

Authors:  J M Bert
Journal:  J Arthroplasty       Date:  1998-12       Impact factor: 4.757

4.  Early failure of the femoral component in unicompartmental knee arthroplasty.

Authors:  G D Riebel; F W Werner; D C Ayers; J Bromka; D G Murray
Journal:  J Arthroplasty       Date:  1995-10       Impact factor: 4.757

5.  [A unicompartment knee prosthesis: the effect of the positioning of the tibial plate on the functional results].

Authors:  L Lootvoet; P Burton; O Himmer; L Pilot; J P Ghosez
Journal:  Acta Orthop Belg       Date:  1997-06       Impact factor: 0.500

6.  [Unicompartmental knee prosthesis].

Authors: 
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1996

7.  Osteoarthrosis of the knee. A radiographic investigation.

Authors:  S Ahlbäck
Journal:  Acta Radiol Diagn (Stockh)       Date:  1968

8.  Use of unicompartmental instead of tricompartmental prostheses for unicompartmental arthrosis in the knee is a cost-effective alternative. 15,437 primary tricompartmental prostheses were compared with 10,624 primary medial or lateral unicompartmental prostheses.

Authors:  O Robertsson; L Borgquist; K Knutson; S Lewold; L Lidgren
Journal:  Acta Orthop Scand       Date:  1999-04

9.  Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden.

Authors:  O Robertsson; M Dunbar; T Pehrsson; K Knutson; L Lidgren
Journal:  Acta Orthop Scand       Date:  2000-06

10.  Unicompartmental knee arthroplasty in middle-aged patients: a 2- to 6-year follow-up evaluation.

Authors:  P A Schai; J T Suh; T S Thornhill; R D Scott
Journal:  J Arthroplasty       Date:  1998-06       Impact factor: 4.757

View more
  32 in total

1.  Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system.

Authors:  L Perlick; H Bäthis; M Tingart; C Perlick; C Lüring; J Grifka
Journal:  Int Orthop       Date:  2004-03-06       Impact factor: 3.075

2.  Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty.

Authors:  Jean-Yves Jenny
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-15       Impact factor: 4.342

3.  [Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study].

Authors:  P R Aldinger; H S Gill; U Schlegel; M Schneider; M Clauss; J W Goodfellow; D W Murray; S J Breusch
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

Review 4.  [The history and development of computer assisted orthopaedic surgery].

Authors:  J-Y Jenny
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

5.  Experiences with computer navigated total knee arthroplasty.

Authors:  Zoltán Bejek; László Sólyom; Miklós Szendrõi
Journal:  Int Orthop       Date:  2006-11-04       Impact factor: 3.075

6.  Navigated non-image-based positioning of the acetabulum during total hip replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri; Jean-Claude Dosch; Marius Uscatu; Eugen Ciobanu
Journal:  Int Orthop       Date:  2007-11-13       Impact factor: 3.075

7.  Computer-assisted revision of total knee arthroplasty.

Authors:  Aymard de Ladoucette
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-21       Impact factor: 4.342

8.  Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty.

Authors:  Mui-Hong Lim; Andras Tallay; John Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-31       Impact factor: 4.342

9.  The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Fink; Sebastian Quirbach; Rene Attal; Katja Tecklenburg; Christian Hoser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-20       Impact factor: 4.342

10.  No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery.

Authors:  Bart Kerens; Martijn G M Schotanus; Bert Boonen; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-26       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.