Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging.

T Schaeffter1, S Weiss, H Eggers, V Rasche.   

Abstract

A balanced fast field echo (FFE) sequence (also referred to as true fast imaging with steady precession (true FISP)), based on projection reconstruction (PR) is evaluated in combination with real-time reconstruction and interactive scanning capabilities for cardiac function studies. Cardiac image sequences obtained with the balanced PR-FFE method are compared with images obtained with a spin-warp (2D Fourier transform (2DFT)) technique. In particular, the representation of motion artifacts in both techniques is investigated. Balanced PR-FFE provides a similar contrast to spin-warp-related techniques, but is less sensitive to motion artifacts. The use of angular undersampling within balanced PR-FFE is examined as a means to increase temporal resolution while causing only minor artifacts. Furthermore, a modification of the profile order allows the reconstruction of PR images at different spatial and temporal resolution levels from the same data. This study shows that balanced PR-FFE is a robust tool for cardiac function studies. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11746592     DOI: 10.1002/mrm.1322

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

2.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

3.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

4.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

5.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

7.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

8.  Validation of highly accelerated real-time cardiac cine MRI with radial k-space sampling and compressed sensing in patients at 1.5T and 3T.

Authors:  Hassan Haji-Valizadeh; Amir A Rahsepar; Jeremy D Collins; Elwin Bassett; Tamara Isakova; Tobias Block; Ganesh Adluru; Edward V R DiBella; Daniel C Lee; James C Carr; Daniel Kim
Journal:  Magn Reson Med       Date:  2017-09-17       Impact factor: 4.668

9.  Real-time free-breathing cardiac imaging with self-calibrated through-time radial GRAPPA.

Authors:  Ozan Sayin; Haris Saybasili; M Muz Zviman; Mark Griswold; Henry Halperin; Nicole Seiberlich; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2016-03-10       Impact factor: 4.668

10.  Accelerated, free-breathing, noncontrast, electrocardiograph-triggered, thoracic MR angiography with stack-of-stars k-space sampling and GRASP reconstruction.

Authors:  Hassan Haji-Valizadeh; Jeremy D Collins; Pascale J Aouad; Ali M Serhal; Marc D Lindley; Jianing Pang; Nivedita K Naresh; James C Carr; Daniel Kim
Journal:  Magn Reson Med       Date:  2018-09-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.