Literature DB >> 11747015

A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence.

C Flask1, D Elgort, E Wong, A Shankaranarayanan, J Lewin, M Wendt, J L Duerk.   

Abstract

This work demonstrates the feasibility of using wireless, tuned fiducial markers with a limited projection reconstruction-fast imaging with steady-state free precession sequence (LPR-FISP) to accurately obtain tracking information necessary for interactive scan plane selection in magnetic resonance imaging (MRI). The position and orientation of a rigid interventional device can be uniquely determined from the 3D coordinates of three fiducial markers mounted in a known configuration on the device. Three fiducial markers were tuned to the proton resonant frequency in a 0.2T open MR scanner and mounted to the surface of a cylindrical water phantom. An LPR-FISP sequence was developed to suppress the water phantom signal while preserving that of the fiducial markers through a nonselective low-tip-angle excitation and a dephaser gradient applied prior to data acquisition. A localization algorithm was developed to accurately calculate the 3D coordinates of the fiducial markers using four LPR-FISP projections in two orthogonal scan planes. The sequence repetition time (TR = 21 msec) and the limited projection set resulted in fast LPR-FISP coordinate acquisition times of approximately 170 msec with an accuracy (max error) of 3 mm on a 0.2T MR system. This fast, accurate tracking method provides the fundamental technology for interactive MRI scan plane definition for rigid interventional devices without the need for stereotactic cameras or reference frames. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11747015     DOI: 10.1002/jmri.1227

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

1.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 2.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

3.  Device localization and dynamic scan plane selection using a wireless magnetic resonance imaging detector array.

Authors:  Matthew J Riffe; Stephen R Yutzy; Yun Jiang; Michael D Twieg; Colin J Blumenthal; Daniel P Hsu; Li Pan; Wesley D Gilson; Jeffrey L Sunshine; Christopher A Flask; Jeffrey L Duerk; Dean Nakamoto; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

4.  Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI.

Authors:  Marc Rea; Donald McRobbie; Haytham Elhawary; Zion T H Tse; Michael Lamperth; Ian Young
Journal:  MAGMA       Date:  2008-09-19       Impact factor: 2.310

5.  Iterative Jacobian-Based Inverse Kinematics and Open-Loop Control of an MRI-Guided Magnetically Actuated Steerable Catheter System.

Authors:  Taoming Liu; Russell Jackson; Dominique Franson; Nate Lombard Poirot; Reinhardt Kam Criss; Nicole Seiberlich; Mark A Griswold; M Cenk Çavuşoğlu
Journal:  IEEE ASME Trans Mechatron       Date:  2017-05-16       Impact factor: 5.303

6.  Echo-planar imaging with prospective slice-by-slice motion correction using active markers.

Authors:  Melvyn B Ooi; Sascha Krueger; Jordan Muraskin; William J Thomas; Truman R Brown
Journal:  Magn Reson Med       Date:  2011-02-24       Impact factor: 4.668

7.  Prospective active marker motion correction improves statistical power in BOLD fMRI.

Authors:  Jordan Muraskin; Melvyn B Ooi; Robin I Goldman; Sascha Krueger; William J Thomas; Paul Sajda; Truman R Brown
Journal:  Neuroimage       Date:  2012-12-05       Impact factor: 6.556

8.  Prospective real-time correction for arbitrary head motion using active markers.

Authors:  Melvyn B Ooi; Sascha Krueger; William J Thomas; Srirama V Swaminathan; Truman R Brown
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

9.  Design and Fabrication of MR-Tracked Metallic Stylet for Gynecologic Brachytherapy.

Authors:  Yue Chen; Wei Wang; Ehud J Schmidt; Ka-Wai Kwok; Akila N Viswanathan; Robert Cormack; Zion Tsz Ho Tse
Journal:  IEEE ASME Trans Mechatron       Date:  2015-11-24       Impact factor: 5.303

10.  Prospective real-time head motion correction using inductively coupled wireless NMR probes.

Authors:  Saikat Sengupta; Sasidhar Tadanki; John C Gore; E Brian Welch
Journal:  Magn Reson Med       Date:  2013-11-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.