Literature DB >> 23910820

Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study.

Genymphas B Higgs1, Josa A Hanzlik, Daniel W MacDonald, Jeremy L Gilbert, Clare M Rimnac, Steven M Kurtz.   

Abstract

This retrieval study documents taper damage at modular interfaces in retrieved MOM THA systems and investigates if increased modularity is associated with increased fretting and corrosion. One hundred thirty-four (134) heads and 60 stems (41 modular necks) of 8 different bearing designs (5 manufacturers) were analyzed. Damage at the shell-liner interface of 18 modular CoCr acetabular liners and the corresponding 11 acetabular shells was also evaluated. The results of this study support the hypothesis that fretting and corrosion damage occurs at a variety of modular component interfaces in contemporary MOM THAs. We also found that modularity of the femoral stem was associated with increased damage at the head. An analysis of component and patient variables revealed that dissimilar alloy pairing, larger head sizes, increased medio-lateral offsets and longer neck moment arms were all associated with increased taper damage at the modular interfaces.
© 2013.

Entities:  

Keywords:  corrosion; fretting; metal on metal; modularity; total hip arthroplasty

Mesh:

Substances:

Year:  2013        PMID: 23910820      PMCID: PMC3971476          DOI: 10.1016/j.arth.2013.05.040

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

1.  In vitro corrosion testing of modular hip tapers.

Authors:  Jay R Goldberg; Jeremy L Gilbert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2003-02-15       Impact factor: 3.368

2.  A multicenter retrieval study of the taper interfaces of modular hip prostheses.

Authors:  Jay R Goldberg; Jeremy L Gilbert; Joshua J Jacobs; Thomas W Bauer; Wayne Paprosky; Sue Leurgans
Journal:  Clin Orthop Relat Res       Date:  2002-08       Impact factor: 4.176

3.  Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.

Authors:  Nadim James Hallab; Carlo Messina; Anastasia Skipor; Joshua J Jacobs
Journal:  J Orthop Res       Date:  2004-03       Impact factor: 3.494

Review 4.  Corrosion of metal orthopaedic implants.

Authors:  J J Jacobs; J L Gilbert; R M Urban
Journal:  J Bone Joint Surg Am       Date:  1998-02       Impact factor: 5.284

5.  Fretting wear in a modular neck hip prosthesis.

Authors:  M Viceconti; M Baleani; S Squarzoni; A Toni
Journal:  J Biomed Mater Res       Date:  1997-05

6.  Histological features of pseudotumor-like tissues from metal-on-metal hips.

Authors:  Pat Campbell; Edward Ebramzadeh; Scott Nelson; Karren Takamura; Koen De Smet; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

7.  Metal release and corrosion effects of modular neck total hip arthroplasty.

Authors:  J Philippe Kretzer; Eike Jakubowitz; Michael Krachler; Marc Thomsen; Christian Heisel
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

8.  Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties.

Authors:  Heiko Meyer; Tina Mueller; Gesine Goldau; Kathrin Chamaon; Marcel Ruetschi; Christoph H Lohmann
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

9.  In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.

Authors:  J L Gilbert; C A Buckley; J J Jacobs
Journal:  J Biomed Mater Res       Date:  1993-12

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more
  36 in total

Review 1.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

Review 2.  Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues.

Authors:  Christoph H Lohmann; Gurpal Singh; Hans-Georg Willert; Gottfried H Buchhorn
Journal:  World J Orthop       Date:  2014-11-18

3.  Characterization of Femoral Head Taper Corrosion Features Using a 22-Year Retrieval Database.

Authors:  Jacob Cartner; Patrick Aldinger; Chenxi Li; David Collins
Journal:  HSS J       Date:  2016-08-12

4.  Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Jeffrey Lange; Amanda Wach; Chelsea N Koch; Robert H Hopper; Henry Ho; Charles A Engh; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

5.  CORR Insights®: Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Ronald Emilio Delanois
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

6.  Is there material loss at the backside taper in modular CoCr acetabular liners?

Authors:  Matthias T Agne; Richard J Underwood; Sevi B Kocagoz; Daniel W MacDonald; Judd S Day; Javad Parvizi; Matthew J Kraay; Michael A Mont; Gregg R Klein; Harold E Cates; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2014-10-16       Impact factor: 4.176

7.  Joint replacement surgery and the innate immune system.

Authors:  Stuart B Goodman; Yrjo T Konttinen; Michiaki Takagi
Journal:  J Long Term Eff Med Implants       Date:  2014

8.  Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty.

Authors:  Craig W Forsthoefel; Nicholas M Brown; Mark L Barba
Journal:  J Orthop       Date:  2017-08-31

Review 9.  Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.

Authors:  Ming Han Lincoln Liow; Young-Min Kwon
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

10.  Mechanically assisted taper corrosion in modular TKA.

Authors:  Christina M Arnholt; Daniel W MacDonald; Mariya Tohfafarosh; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz; Gregg Klein; Michael A Mont; Javad Parvizi; Harold E Cates; Gwo-Chin Lee; Arthur Malkani; Mattheuw Kraay
Journal:  J Arthroplasty       Date:  2014-05-28       Impact factor: 4.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.