Dosimetry of therapeutic photon beams using an extended dose range film.

Jacqueline Esthappan1, Sasa Mutic, William B Harms, James F Dempsey, Daniel A Low.   

Abstract

For intensity modulated radiation therapy (IMRT) dose distribution verification, multidimensional measurements are required to quantify the steep dose-gradient regions. High resolution, two-dimensional dose distributions can be measured using radiographic film. However, the photon energy response of film is known to be a function of depth, field size, and photon beam energy, potentially reducing the accuracy of dose distribution measurements. The dosimetric properties of the recently developed Kodak EDR2 film were investigated and compared to those of Kodak XV film. The dose responses of both film types to 6 MV and 18 MV photon beams were investigated for depths of 5 cm, 10 cm, and 15 cm and field sizes of 4x4 cm2 and 15x15 cm2. This analysis involved the determination of sensitometric curves for XV and EDR2 films, the determination of dose profiles from exposed XV and EDR2 films, and comparison of the film-generated dose profiles to ionization chamber measurements. For the combinations of photon beam energy, depth, and field size investigated here, our results indicate that the sensitometric curves are nearly independent of field size and depth of calibration. For a field size of 4x4 cm2, a single sensitometric curve for either EDR2 and XV film can be used for the determination of relative dose profiles. For the larger field size, the sensitometric curve for EDR2 film is superior to XV film in regions where the dose falls below 20% of the central axis dose, due to the effects that the increased low energy scattered photon contributions have on film response. The limited field size and depth dependence of sensitometric data measured using EDR2 film, along with the inherently wide linear dose-response range of EDR2 film, makes it better suited to the verification of IMRT dose distributions.

Entities:  

Mesh:

Year:  2002        PMID: 12408321     DOI: 10.1118/1.1508379

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Quasi-IMAT study with conventional equipment to show high plan quality with a single gantry arc.

Authors:  Judith Alvarez Moret; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

2.  A calibration method for patient specific IMRT QA using a single therapy verification film.

Authors:  Arvind Kumar Shukla; Arun S Oinam; Sanjeev Kumar; I S Sandhu; S C Sharma
Journal:  Rep Pract Oncol Radiother       Date:  2013-05-24

3.  Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.

Authors:  S Suriyapee; N Pitaxtarnin; S Oonsiri; C Jumpangern; I Israngkul Na Ayuthaya
Journal:  Biomed Imaging Interv J       Date:  2008-01-01

4.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

5.  A comparison of two commercial treatment-planning systems to IMRT.

Authors:  M Peter Petric; Brenda G Clark; James L Robar
Journal:  J Appl Clin Med Phys       Date:  2005-08-12       Impact factor: 2.102

6.  Technical evaluation of TomoTherapy automatic roll correction.

Authors:  Steve Laub; Michael Snyder; Jay Burmeister
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

7.  Comprehensive validation of halcyon 2.0 plans and the implementation of patient specific QA with multiple detector platforms.

Authors:  Eric Laugeman; Ana Heermann; Jessica Hilliard; Michael Watts; Marshia Roberson; Robert Morris; Sreekrishna Goddu; Abhishek Sethi; Imran Zoberi; Hyun Kim; Sasa Mutic; Geoffrey Hugo; Bin Cai
Journal:  J Appl Clin Med Phys       Date:  2020-05-05       Impact factor: 2.102

8.  Comparative Study between Measurement Data and Treatment Planning System (TPS) in Small Fields for High Energy Photon Beams.

Authors:  Khaled El Shahat; Aziza El Saeid; Ehab Attalla; Adel Yassin
Journal:  ISRN Oncol       Date:  2014-05-06

9.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

10.  Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

Authors:  Ross I Berbeco; Cynthia J Pope; Steve B Jiang
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.