Literature DB >> 12210952

Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator.

Marcello Alecci1, Peter Jezzard.   

Abstract

Radiofrequency (RF) shields that surround MRI transmit/receive coils should provide effective RF screening, without introducing unwanted eddy currents induced by gradient switching. Results are presented from a detailed examination of an effective RF shield design for a prototype transverse electromagnetic (TEM) resonator suitable for use at 3 Tesla. It was found that effective RF shielding and low eddy current sensitivity could be achieved by axial segmentation (gap width = 2.4 mm) of a relatively thick (35 microm) copper shield, etched on a kapton polyimide substrate. This design has two main advantages: first, it makes the TEM less sensitive to the external environment and RF interference; and second, it makes the RF shield mechanically robust and easy to handle and assemble. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12210952     DOI: 10.1002/mrm.10226

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.

Authors:  Yujuan Zhao; Tiejun Zhao; Shailesh B Raval; Narayanan Krishnamurthy; Hai Zheng; Chad T Harris; William B Handler; Blaine A Chronik; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2014-11-03       Impact factor: 4.668

2.  Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.

Authors:  Ioannis Lavdas; Hugh C Seton; Charles R Harrington; Claude M Wischik
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

3.  Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions.

Authors:  Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Wenmiao Lu; Scott B Reeder; R Scott Hinks; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

4.  Transparent thin shield for radio frequency transmit coils.

Authors:  Debra S Rivera; Jessica Schulz; Thomas Siegert; Verena Zuber; Robert Turner
Journal:  MAGMA       Date:  2014-05-27       Impact factor: 2.310

5.  Low eddy current RF shielding enclosure designs for 3T MR applications.

Authors:  Brian J Lee; Ronald D Watkins; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2017-06-06       Impact factor: 4.668

6.  Feasibility study of a unilateral RF array coil for MR-scintimammography.

Authors:  Seunghoon Ha; Mark J Hamamura; Werner W Roeck; James Hugg; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Phys Med Biol       Date:  2011-10-05       Impact factor: 3.609

7.  Parallel transmission RF pulse design for eddy current correction at ultra high field.

Authors:  Hai Zheng; Tiejun Zhao; Yongxian Qian; Tamer Ibrahim; Fernando Boada
Journal:  J Magn Reson       Date:  2012-03-28       Impact factor: 2.229

8.  Rapid measurement and correction of phase errors from B0 eddy currents: impact on image quality for non-Cartesian imaging.

Authors:  Ethan K Brodsky; Jessica L Klaers; Alexey A Samsonov; Richard Kijowski; Walter F Block
Journal:  Magn Reson Med       Date:  2012-04-05       Impact factor: 4.668

9.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

10.  MR phase imaging with bipolar acquisition.

Authors:  Joseph Dagher; Kambiz Nael
Journal:  NMR Biomed       Date:  2016-05-05       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.