Literature DB >> 27149433

MR phase imaging with bipolar acquisition.

Joseph Dagher1, Kambiz Nael2.   

Abstract

We have previously proposed a novel magnetic resonance (MR) phase imaging framework (MAGPI) based on a three-echo sequence that demonstrated substantial gains in phase signal-to-noise ratio (SNR). We improve upon the performance of MAGPI by extending the formulation to handle (i) an alternating gradient polarity (bipolar) readout scheme and (ii) an arbitrary number of echoes. We formulate the phase-imaging problem using maximum-likelihood (ML) estimation. The acquisition uses an optimized multi-echo gradient echo (MEGE) sequence. The tissue-phase estimation algorithm is a voxel-per-voxel approach, which requires no reference scans, no phase unwrapping and no spatial denoising. Unlike other methods, our bipolar readout model is general and does not make simplifying assumptions about the even-odd echo phase errors. The results show that (a) our proposed bipolar MAGPI approach improves on the phase SNR gains achieved with monopolar MAGPI and (b) the phase SNR converges with the number of echoes more rapidly with bipolar MAGPI. Importantly, bipolar MAGPI enables phase imaging in severely SNR-constrained scenarios, where monopolar MAGPI is unable to find solutions. The substantial phase SNR gains achieved with our framework are used here to (a) accelerate acquisitions (full brain 0.89 mm in-plane resolution in 2 min 30 sec) and (b) enable high-contrast high-resolution phase imaging (310 µm in-plane resolution) at clinical field strengths.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  MR phase; bipolar; coil array; eddy current; maximum likelihood; multi-echo; non-flyback; phase offset

Mesh:

Year:  2016        PMID: 27149433      PMCID: PMC5097709          DOI: 10.1002/nbm.3523

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  24 in total

1.  Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator.

Authors:  Marcello Alecci; Peter Jezzard
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

2.  Quantitative susceptibility mapping for investigating subtle susceptibility variations in the human brain.

Authors:  Ferdinand Schweser; Karsten Sommer; Andreas Deistung; Jürgen Rainer Reichenbach
Journal:  Neuroimage       Date:  2012-06-01       Impact factor: 6.556

3.  Quantitative imaging of intrinsic magnetic tissue properties using MRI signal phase: an approach to in vivo brain iron metabolism?

Authors:  Ferdinand Schweser; Andreas Deistung; Berengar Wendel Lehr; Jürgen Rainer Reichenbach
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

Review 4.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

5.  Magnetic resonance elastography with a phased-array acoustic driver system.

Authors:  Yogesh K Mariappan; Phillip J Rossman; Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

6.  Combining phase images from multi-channel RF coils using 3D phase offset maps derived from a dual-echo scan.

Authors:  Simon Robinson; Günther Grabner; Stephan Witoszynskyj; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2011-01-19       Impact factor: 4.668

7.  MAGPI: A framework for maximum likelihood MR phase imaging using multiple receive coils.

Authors:  Joseph Dagher; Kambiz Nael
Journal:  Magn Reson Med       Date:  2015-05-06       Impact factor: 4.668

8.  A novel background field removal method for MRI using projection onto dipole fields (PDF).

Authors:  Tian Liu; Ildar Khalidov; Ludovic de Rochefort; Pascal Spincemaille; Jing Liu; A John Tsiouris; Yi Wang
Journal:  NMR Biomed       Date:  2011-03-08       Impact factor: 4.044

9.  Regularized field map estimation in MRI.

Authors:  Amanda K Funai; Jeffrey A Fessler; Desmond T B Yeo; Valur T Olafsson; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

10.  A Joint Acquisition-Estimation Framework for MR Phase Imaging.

Authors:  Joseph Dagher
Journal:  Inf Process Med Imaging       Date:  2015
View more
  2 in total

1.  Maximum AmbiGuity Distance for Phase Imaging in Detection of Traumatic Cerebral Microbleeds: An Improvement over Current Imaging Practice.

Authors:  K Nael; J C Dagher; M E Downs; M S Fine; E Brokaw; D Millward
Journal:  AJNR Am J Neuroradiol       Date:  2020-10-08       Impact factor: 3.825

2.  Reproducibility of liver iron concentration estimates in MRI through R2* measurement determined by least-squares curve fitting.

Authors:  Andrew M Headley; Jared V Grice; David R Pickens
Journal:  J Appl Clin Med Phys       Date:  2020-11-18       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.