Literature DB >> 22789452

Parallel transmission RF pulse design for eddy current correction at ultra high field.

Hai Zheng1, Tiejun Zhao, Yongxian Qian, Tamer Ibrahim, Fernando Boada.   

Abstract

Multidimensional spatially selective RF pulses have been used in MRI applications such as B₁ and B₀ inhomogeneities mitigation. However, the long pulse duration has limited their practical applications. Recently, theoretical and experimental studies have shown that parallel transmission can effectively shorten pulse duration without sacrificing the quality of the excitation pattern. Nonetheless, parallel transmission with accelerated pulses can be severely impeded by hardware and/or system imperfections. One of such imperfections is the effect of the eddy current field. In this paper, we first show the effects of the eddy current field on the excitation pattern and then report an RF pulse the design method to correct eddy current fields caused by the RF coil and the gradient system. Experimental results on a 7 T human eight-channel parallel transmit system show substantial improvements on excitation patterns with the use of eddy current correction. Moreover, the proposed model-based correction method not only demonstrates comparable excitation patterns as the trajectory measurement method, but also significantly improves time efficiency.
Copyright © 2012. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22789452      PMCID: PMC3418061          DOI: 10.1016/j.jmr.2012.03.017

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  15 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator.

Authors:  Marcello Alecci; Peter Jezzard
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

4.  Parallel RF transmission with eight channels at 3 Tesla.

Authors:  Kawin Setsompop; Lawrence L Wald; Vijayanand Alagappan; Borjan Gagoski; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

5.  Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients.

Authors:  Ian C Atkinson; Aiming Lu; Keith R Thulborn
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

6.  Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels.

Authors:  K Setsompop; L L Wald; V Alagappan; B A Gagoski; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

7.  A three-dimensional spin-echo or inversion pulse.

Authors:  J M Pauly; B S Hu; S J Wang; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1993-01       Impact factor: 4.668

8.  A novel eddy current compensation scheme for pulsed gradient systems.

Authors:  R E Wysong; D P Madio; I J Lowe
Journal:  Magn Reson Med       Date:  1994-05       Impact factor: 4.668

9.  Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

Authors:  Hai Zheng; Tiejun Zhao; Yongxian Qian; Tamer S Ibrahim; Fernando E Boada
Journal:  Magn Reson Med       Date:  2011-04-21       Impact factor: 4.668

10.  Parallel excitation in the human brain at 9.4 T counteracting k-space errors with RF pulse design.

Authors:  Xiaoping Wu; J Thomas Vaughan; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more
  2 in total

1.  Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.

Authors:  Yujuan Zhao; Tiejun Zhao; Shailesh B Raval; Narayanan Krishnamurthy; Hai Zheng; Chad T Harris; William B Handler; Blaine A Chronik; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2014-11-03       Impact factor: 4.668

2.  VERSE-guided parallel RF excitations using dynamic field correction.

Authors:  Mustafa Çavuşoğlu; Ronald Mooiweer; Klaas P Pruessmann; Shaihan J Malik
Journal:  NMR Biomed       Date:  2017-02-17       Impact factor: 4.044

  2 in total