Literature DB >> 12210916

Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging.

Yiping P Du1, Xiaohong Joe Zhou, Matt A Bernstein.   

Abstract

Echo-planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo-planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher-order magnetic field concomitant with the linear magnetic field gradient, or the concomitant magnetic field. The image distortion caused by the concomitant magnetic field is more prominent when a higher gradient amplitude is used for readout. It is also shown that the concomitant magnetic field can cause ghosting and blurring. A theoretical analysis is performed for the concomitant field effect in nonaxial EPI images. A point-by-point (or line-by-line) phase correction algorithm is developed to correct the image distortion, ghosting, and blurring. A postreconstruction processing algorithm is also developed to correct image distortion with much higher computational efficiency. Experimental results show that both correction methods effectively reduce the image distortion in coronal or sagittal images. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 12210916     DOI: 10.1002/mrm.10249

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results.

Authors:  M Okan Irfanoglu; Lindsay Walker; Joelle Sarlls; Stefano Marenco; Carlo Pierpaoli
Journal:  Neuroimage       Date:  2012-03-03       Impact factor: 6.556

2.  B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

Authors:  Paul T Weavers; Shengzhen Tao; Joshua D Trzasko; Louis M Frigo; Yunhong Shu; Matthew A Frick; Seung-Kyun Lee; Thomas K-F Foo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

3.  Image artifacts in very low magnetic field MRI: the role of concomitant gradients.

Authors:  Dmitriy A Yablonskiy; Alexander L Sukstanskii; Joseph J H Ackerman
Journal:  J Magn Reson       Date:  2005-06       Impact factor: 2.229

4.  Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging.

Authors:  Joseph Y Cheng; Juan M Santos; John M Pauly
Journal:  Magn Reson Med       Date:  2011-03-07       Impact factor: 4.668

5.  Characterization of hardware-related spatial distortions for IR-PETRA pulse sequence using a brain specific phantom.

Authors:  Sima Ahmadian; Iraj Jabbari; Seyed Mehdi Bagherimofidi; Hamidreza Saligheh Rad
Journal:  MAGMA       Date:  2020-07-06       Impact factor: 2.310

6.  Technical Note: Compact three-tesla magnetic resonance imager with high-performance gradients passes ACR image quality and acoustic noise tests.

Authors:  Paul T Weavers; Yunhong Shu; Shengzhen Tao; John Huston; Seung-Kyun Lee; Dominic Graziani; Jean-Baptiste Mathieu; Joshua D Trzasko; Thomas K-F Foo; Matt A Bernstein
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

7.  Maxwell-compensated design of asymmetric gradient waveforms for tensor-valued diffusion encoding.

Authors:  Filip Szczepankiewicz; Carl-Fredrik Westin; Markus Nilsson
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

8.  DR-BUDDI (Diffeomorphic Registration for Blip-Up blip-Down Diffusion Imaging) method for correcting echo planar imaging distortions.

Authors:  M Okan Irfanoglu; Pooja Modi; Amritha Nayak; Elizabeth B Hutchinson; Joelle Sarlls; Carlo Pierpaoli
Journal:  Neuroimage       Date:  2014-11-26       Impact factor: 6.556

9.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

10.  Steer-PROP: a GRASE-PROPELLER sequence with interecho steering gradient pulses.

Authors:  Girish Srinivasan; Novena Rangwala; Xiaohong Joe Zhou
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.