Image artifacts in very low magnetic field MRI: the role of concomitant gradients.

Dmitriy A Yablonskiy1, Alexander L Sukstanskii, Joseph J H Ackerman.   

Abstract

While MRI at very low magnetic fields has certain potential advantages, it may also face problems that are not typical for MRI at conventional and high field (0.1-10T). Major differences arise due to the presence of concomitant components of inhomogeneous magnetic field (gradients) that are transverse to the major B(z) field, B(0). These concomitant transverse field components are inevitably generated by the same gradient coils that generate desired B(z) imaging gradients as routinely used in MRI for spatial encoding. In the hypothetical case (linear spatial variation of B(z) field amplitude due to the imaging gradients, no concomitant transverse field components, no B(0) and B(1) field inhomogeneities, etc.), Fourier transform MRI preserves the shape of the real object being examined. It is demonstrated herein that unavoidable concomitant transverse field gradients, G, result in an image deformation of the object's actual shape by bending straight lines and planes with a characteristic curvature radius R(c)=B(0)/G. For imaging gradients on the order of 10 mT/m and B(0) of 1T, the radius R(c) is about 100 m and image distortions are generally negligible. However, for B(0) of 1 mT, R(c) is 10 cm, which is less than a typical FOV in human studies. This manuscript derives expressions describing geometrical relationships between the imaged object and the obtained MR data. In addition to geometrical distortions, image intensity will be modulated in a complex, spatially dependent manner. Hence, if unaccounted for, corresponding image distortions-geometry and intensity-will create substantial difficulties in very low field image interpretation.

Entities:  

Mesh:

Year:  2005        PMID: 15862245      PMCID: PMC2140255          DOI: 10.1016/j.jmr.2005.02.016

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  15 in total

1.  In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields.

Authors:  Christopher P Bidinosti; Jamal Choukeife; Pierre Jean Nacher; Geneviève Tastevin
Journal:  J Magn Reson       Date:  2003-05       Impact factor: 2.229

2.  MRI of the lung gas-space at very low-field using hyperpolarized noble gases.

Authors:  Arvind K Venkatesh; Adelaide X Zhang; Joey Mansour; Lyubov Kubatina; Chang Hyun Oh; Gregory Blasche; M Selim Unlü; Dilip Balamore; Ferenc A Jolesz; Bennett B Goldberg; Mitchell S Albert
Journal:  Magn Reson Imaging       Date:  2003-09       Impact factor: 2.546

3.  SQUID detected NMR in microtesla magnetic fields.

Authors:  Andrei N Matlachov; Petr L Volegov; Michelle A Espy; John S George; Robert H Kraus
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

4.  SQUID-detected MRI at 132 microT with T1-weighted contrast established at 10 microT--300 mT.

Authors:  Seung Kyun Lee; Michael Mössle; Whittier Myers; Nathan Kelso; Andreas H Trabesinger; Alexander Pines; John Clarke
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

5.  Self-diffusion imaging by spin echo in Earth's magnetic field.

Authors:  A Mohoric; J Stepisnik; M Kos
Journal:  J Magn Reson       Date:  1999-01       Impact factor: 2.229

6.  Concomitant gradient terms in phase contrast MR: analysis and correction.

Authors:  M A Bernstein; X J Zhou; J A Polzin; K F King; A Ganin; N J Pelc; G H Glover
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

7.  Concomitant magnetic-field-induced artifacts in axial echo planar imaging.

Authors:  X J Zhou; Y P Du; M A Bernstein; H G Reynolds; J K Maier; J A Polzin
Journal:  Magn Reson Med       Date:  1998-04       Impact factor: 4.668

8.  Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths.

Authors:  D G Norris; J M Hutchison
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

9.  Nonaxial whole-body instant imaging.

Authors:  R M Weisskoff; M S Cohen; R R Rzedzian
Journal:  Magn Reson Med       Date:  1993-06       Impact factor: 4.668

10.  Biological magnetic resonance imaging using laser-polarized 129Xe.

Authors:  M S Albert; G D Cates; B Driehuys; W Happer; B Saam; C S Springer; A Wishnia
Journal:  Nature       Date:  1994-07-21       Impact factor: 49.962

View more
  8 in total

1.  Parallel MRI at microtesla fields.

Authors:  Vadim S Zotev; Petr L Volegov; Andrei N Matlashov; Michelle A Espy; John C Mosher; Robert H Kraus
Journal:  J Magn Reson       Date:  2008-03-06       Impact factor: 2.229

2.  Posture-dependent human 3He lung imaging in an open-access MRI system: initial results.

Authors:  Leo L Tsai; Ross W Mair; Chih-Hao Li; Matthew S Rosen; Samuel Patz; Ronald L Walsworth
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

3.  An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging.

Authors:  L L Tsai; R W Mair; M S Rosen; S Patz; R L Walsworth
Journal:  J Magn Reson       Date:  2008-05-24       Impact factor: 2.229

4.  Noise amplification in parallel whole-head ultra-low-field magnetic resonance imaging using 306 detectors.

Authors:  Fa-Hsuan Lin; Panu T Vesanen; Jaakko O Nieminen; Yi-Cheng Hsu; Koos C J Zevenhoven; Juhani Dabek; Lauri T Parkkonen; Andrey Zhdanov; Risto J Ilmoniemi
Journal:  Magn Reson Med       Date:  2012-09-28       Impact factor: 4.668

5.  Optically polarized 3He.

Authors:  T R Gentile; P J Nacher; B Saam; T G Walker
Journal:  Rev Mod Phys       Date:  2017-12-11       Impact factor: 54.494

6.  250 MHz Rapid Scan Cross Loop Resonator.

Authors:  Laura A Buchanan; Lukas B Woodcock; George A Rinard; Richard W Quine; Yilin Shi; Sandra S Eaton; Gareth R Eaton
Journal:  Appl Magn Reson       Date:  2018-10-03       Impact factor: 0.831

7.  EMF exposure variation among MRI sequences from pediatric examination protocols.

Authors:  Jennifer Frankel; Kjell Hansson Mild; Johan Olsrud; Jonna Wilén
Journal:  Bioelectromagnetics       Date:  2018-11-30       Impact factor: 2.010

Review 8.  Magnetic Guiding with Permanent Magnets: Concept, Realization and Applications to Nanoparticles and Cells.

Authors:  Peter Blümler
Journal:  Cells       Date:  2021-10-09       Impact factor: 6.600

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.