Literature DB >> 21384423

Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging.

Joseph Y Cheng1, Juan M Santos, John M Pauly.   

Abstract

Non-Cartesian imaging provides many advantages in terms of flexibility, functionality, and speed. However, a major drawback to these imaging methods is off-resonance distortion artifacts. These artifacts manifest as blurring in spiral imaging. Common techniques that remove the off-resonance field inhomogeneity distortion effects are not sufficient, because the high order concomitant gradient fields are nontrivial for common imaging conditions, such as imaging 5 cm off isocenter in an 1.5 T scanner. Previous correction algorithms are either slow or do not take into account the known effects of concomitant gradient fields along with the field inhomogeneities. To ease the correction, the distortion effects are modeled as a non-stationary convolution problem. In this work, two fast and accurate postgridding algorithms are presented and analyzed. These methods account for both the concomitant field effects and the field inhomogeneities. One algorithm operates in the frequency domain and the other in the spatial domain. To take advantage of their speed and accuracy, the algorithms are applied to a real-time cardiac study and a high-resolution cardiac study. Both of the presented algorithms provide for a practical solution to the off-resonance problem in spiral imaging. Copyright &© 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21384423      PMCID: PMC3158031          DOI: 10.1002/mrm.22802

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Off-resonance correction of MR images.

Authors:  H Schomberg
Journal:  IEEE Trans Med Imaging       Date:  1999-06       Impact factor: 10.048

2.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

3.  A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom.

Authors:  Deming Wang; David M Doddrell
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

4.  Rapid in vivo proton shimming.

Authors:  E Schneider; G Glover
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

5.  Geometric distortion in clinical MRI systems Part I: evaluation using a 3D phantom.

Authors:  Deming Wang; Wendy Strugnell; Gary Cowin; David M Doddrell; Richard Slaughter
Journal:  Magn Reson Imaging       Date:  2004-11       Impact factor: 2.546

6.  Characterization, prediction, and correction of geometric distortion in 3 T MR images.

Authors:  Lesley N Baldwin; Keith Wachowicz; Steven D Thomas; Ryan Rivest; B Gino Fallone
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

7.  Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

Authors:  Weitian Chen; Christopher T Sica; Craig H Meyer
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

8.  Simulated phase evolution rewinding (SPHERE): a technique for reducing B0 inhomogeneity effects in MR images.

Authors:  Y M Kadah; X Hu
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

9.  Improved automatic off-resonance correction without a field map in spiral imaging.

Authors:  L C Man; J M Pauly; A Macovski
Journal:  Magn Reson Med       Date:  1997-06       Impact factor: 4.668

10.  A practical acceleration algorithm for real-time imaging.

Authors:  Uygar Sümbül; Juan M Santos; John M Pauly
Journal:  IEEE Trans Med Imaging       Date:  2009-08-25       Impact factor: 10.048

View more
  12 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

2.  Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.

Authors:  Marta Vidorreta; Evelyne Balteau; Ze Wang; Enrico De Vita; María A Pastor; David L Thomas; John A Detre; María A Fernández-Seara
Journal:  NMR Biomed       Date:  2014-09-26       Impact factor: 4.044

3.  A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories.

Authors:  Samuel W Fielden; Craig H Meyer
Journal:  Magn Reson Med       Date:  2014-03-06       Impact factor: 4.668

4.  B0 mapping using rewinding trajectories (BMART).

Authors:  Corey A Baron; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-08-24       Impact factor: 4.668

5.  Simple method for MR gradient system characterization and k-space trajectory estimation.

Authors:  Nii Okai Addy; Holden H Wu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

6.  Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences.

Authors:  Marta Vidorreta; Ze Wang; Ignacio Rodríguez; María A Pastor; John A Detre; María A Fernández-Seara
Journal:  Neuroimage       Date:  2012-11-07       Impact factor: 6.556

7.  Self-gated 3D stack-of-spirals UTE pulmonary imaging at 0.55T.

Authors:  Ahsan Javed; Rajiv Ramasawmy; Kendall O'Brien; Christine Mancini; Pan Su; Waqas Majeed; Thomas Benkert; Himanshu Bhat; Anthony F Suffredini; Ashkan Malayeri; Adrienne E Campbell-Washburn
Journal:  Magn Reson Med       Date:  2021-11-16       Impact factor: 3.737

8.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

9.  Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

Authors:  Shengzhen Tao; Paul T Weavers; Joshua D Trzasko; Yunhong Shu; John Huston; Seung-Kyun Lee; Louis M Frigo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2016-07-04       Impact factor: 4.668

Review 10.  Real-Time Magnetic Resonance Imaging.

Authors:  Krishna S Nayak; Yongwan Lim; Adrienne E Campbell-Washburn; Jennifer Steeden
Journal:  J Magn Reson Imaging       Date:  2020-12-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.