Literature DB >> 12118599

Operator-free, film-based 3D seed reconstruction in brachytherapy.

D A Todor1, G N Cohen, H I Amols, M Zaider.   

Abstract

In brachytherapy implants, the accuracy of dose calculation depends on the ability to localize radioactive sources correctly. If performed manually using planar images, this is a time-consuming and often error-prone process-primarily because each seed must be identified on (at least) two films. In principle, three films should allow automatic seed identification and position reconstruction; however, practical implementation of the numerous algorithms proposed so far appears to have only limited reliability. The motivation behind this work is to create a fast and reliable system for real-time implant evaluation using digital planar images obtained from radiotherapy simulators, or mobile x-ray/fluoroscopy systems. We have developed algorithms and code for 3D seed coordinate reconstruction. The input consists of projections of seed positions in each of three isocentric images taken at arbitrary angles. The method proposed here consists of a set of heuristic rules (in a sense, a learning algorithm) that attempts to minimize seed misclassifications. In the clinic, this means that the system must be impervious to errors resulting from patient motion as well as from finite tolerances accepted in equipment settings. The software program was tested with simulated data, a pelvic phantom and patient data. One hundred and twenty permanent prostate implants were examined (105 125I and 15 103Pd) with the number of seeds ranging from 35 to 138 (average 79). The mean distance between actual and reconstructed seed positions is in the range 0.03-0.11 cm. On a Pentium III computer at 600 MHz the reconstruction process takes 10-30 s. The total number of seeds is independently validated. The process is robust and able to account for errors introduced in the clinic.

Entities:  

Mesh:

Year:  2002        PMID: 12118599     DOI: 10.1088/0031-9155/47/12/303

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

3.  Prostate brachytherapy seed localization with Gaussian blurring and camera self-calibration.

Authors:  Junghoon Lee; Xiaofeng Liu; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  TOMOSYNTHESIS-BASED RADIOACTIVE SEED LOCALIZATION IN PROSTATE BRACHYTHERAPY USING MODIFIED DISTANCE MAP IMAGES.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Jerry L Prince; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-05-14

5.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

7.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

9.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

10.  Intra-operative dosimetry of trans-rectal ultrasound guided I prostate implants using C-arm fluoroscopic images.

Authors:  Paul B Ravindran; C Lewis; J Van Dyk; D D'Souza
Journal:  J Med Phys       Date:  2006-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.