Literature DB >> 19605321

Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Junghoon Lee1, Xiaofeng Liu, Ameet K Jain, Danny Y Song, Everette C Burdette, Jerry L Prince, Gabor Fichtinger.   

Abstract

Intraoperative dosimetry in prostate brachytherapy requires localization of the implanted radioactive seeds. A tomosynthesis-based seed reconstruction method is proposed. A three-dimensional volume is reconstructed from Gaussian-blurred projection images and candidate seed locations are computed from the reconstructed volume. A false positive seed removal process, formulated as an optimal coverage problem, iteratively removes "ghost" seeds that are created by tomosynthesis reconstruction. In an effort to minimize pose errors that are common in conventional C-arms, initial pose parameter estimates are iteratively corrected by using the detected candidate seeds as fiducials, which automatically "focuses" the collected images and improves successive reconstructed volumes. Simulation results imply that the implanted seed locations can be estimated with a detection rate of > or = 97.9% and > or = 99.3% from three and four images, respectively, when the C-arm is calibrated and the pose of the C-arm is known. The algorithm was also validated on phantom data sets successfully localizing the implanted seeds from four or five images. In a Phase-1 clinical trial, we were able to localize the implanted seeds from five intraoperative fluoroscopy images with 98.8% (STD=1.6) overall detection rate.

Entities:  

Mesh:

Year:  2009        PMID: 19605321      PMCID: PMC2790003          DOI: 10.1109/TMI.2009.2026412

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  33 in total

1.  Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

Authors:  G Messaris; Z Kolitsi; C Badea; N Pallikarakis
Journal:  Med Eng Phys       Date:  1999-03       Impact factor: 2.242

2.  FTRAC--a robust fluoroscope tracking fiducial.

Authors:  Ameet Kumar Jain; Tabish Mustafa; Yu Zhou; Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

3.  Demonstration of a forward iterative method to reconstruct brachytherapy seed configurations from x-ray projections.

Authors:  Martin J Murphy; Dorin A Todor
Journal:  Phys Med Biol       Date:  2005-05-18       Impact factor: 3.609

4.  Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL).

Authors:  Ameet Kumar Jain; Yu Zhou; Tabish Mustufa; E Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

5.  C-arm calibration--is it really necessary?

Authors:  Ameet Jain; Ryan Kon; Yu Zhou; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

6.  Brachytherapy seed localization using geometric and linear programming techniques.

Authors:  Vikas Singh; Lopamudra Mukherjee; Jinhui Xu; Kenneth R Hoffmann; Petru M Dinu; Matthew Podgorsak
Journal:  IEEE Trans Med Imaging       Date:  2007-09       Impact factor: 10.048

7.  Prostate brachytherapy seed reconstruction using an adaptive grouping technique.

Authors:  Yi Su; Brian J Davis; Keith M Furutani; Michael G Herman; Richard A Robb
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

8.  Two-film brachytherapy reconstruction algorithm.

Authors:  R L Siddon; L M Chin
Journal:  Med Phys       Date:  1985 Jan-Feb       Impact factor: 4.071

9.  Cancer statistics, 2008.

Authors:  Ahmedin Jemal; Rebecca Siegel; Elizabeth Ward; Yongping Hao; Jiaquan Xu; Taylor Murray; Michael J Thun
Journal:  CA Cancer J Clin       Date:  2008-02-20       Impact factor: 508.702

10.  Fluoroscopy guided transperineal percutaneous permanent 125iodine implantation of prostate cancer.

Authors:  P P Kumar; R R Good; B E Epstein; M B Hussain; F F Bartone
Journal:  Radiat Med       Date:  1985 Jul-Sep
View more
  8 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  C-arm rotation encoding with accelerometers.

Authors:  Victor Grzeda; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-04-10       Impact factor: 2.924

3.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

4.  Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures.

Authors:  Ashvin K George; Merdim Sonmez; Robert J Lederman; Anthony Z Faranesh
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

6.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

7.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

8.  Deformable registration of X-ray to MRI for post-implant dosimetry in prostate brachytherapy.

Authors:  Seyoun Park; Danny Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.