Literature DB >> 11865992

A slot-scanned photodiode-array/CCD hybrid detector for digital mammography.

James G Mainprize1, Nancy L Ford, Shi Yin, Türmay Tümer, Martin J Yaffe.   

Abstract

We have developed a novel direct conversion detector for use in a slot-scanning digital mammography system. The slot-scan concept allows for dose efficient scatter rejection and the ability to use small detectors to produce a large-area image. The detector is a hybrid design with a 1.0 mm thick silicon PIN photodiode array (the x-ray absorber) indium-bump bonded to a CCD readout that is operated in time-delay integration (TDI) mode. Because the charge capacity requirement for good image quality exceeds the capabilities of standard CCDs, a novel CCD was developed. This CCD consists of 24 independent sections, each acting as a miniature CCD with eight rows for TDI. The signal from each section is combined off-chip to produce a full signal image. The MTF and DQE for the device was measured at several exposures and compared to a linear systems model of signal and noise propagation. Because of the scanning nature of TDI imaging, both the MTF(f) and DQE(f) are reduced along the direction of the scanning motion. For a 26 kVp spectrum, the DQE(0) was measured to be 0.75+/-0.02 for an exposure of 1.29 x 10(-5) C/kg (50 mR).

Entities:  

Mesh:

Year:  2002        PMID: 11865992     DOI: 10.1118/1.1446108

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Evaluation of scatter effects on image quality for breast tomosynthesis.

Authors:  Gang Wu; James G Mainprize; John M Boone; Martin J Yaffe
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

4.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Authors:  Xinming Liu; Chris C Shaw; Mustafa C Altunbas; Tianpeng Wang
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

6.  Slot-scan digital radiography of the lower extremities: a comparison to computed radiography with respect to image quality and radiation dose.

Authors:  Kwang Hwi Lee; Jong Won Kwon; Young Cheol Yoon; Sang Hee Choi; Jee Young Jung; Ji Hye Kim; Sang Jun Lee
Journal:  Korean J Radiol       Date:  2009 Jan-Feb       Impact factor: 3.500

7.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

8.  A static multi-slit collimator system for scatter reduction in cone-beam CT.

Authors:  Jina Chang; Siyong Kim; Doh-Yun Jang; Tae-Suk Suh
Journal:  J Appl Clin Med Phys       Date:  2010-10-07       Impact factor: 2.102

  8 in total