The effect of decreasing mAs on image quality and patient dose in sinus CT.

S A Sohaib1, P D Peppercorn, J A Horrocks, M H Keene, G S Kenyon, R H Reznek.   

Abstract

The aim of this study was to determine the effect of reducing mAs on the diagnostic quality of images and the radiation dose to the orbits in patients undergoing sinus CT. We studied 40 consecutive patients undergoing paranasal sinus CT for inflammatory disease prior to functional endoscopic sinus surgery (FESS). Four groups of 10 patients were scanned at 200 mAs, 150 mAs, 100 mAs and 50 mAs, respectively. Orbital radiation dose was measured using thermoluminescent dosemeters. Images were reviewed independently by two observers who were unaware of the mAs setting used. Image quality was evaluated using a semi-quantitative scoring system for six anatomical structures. The osteomeatal complex, uncinate process, infundibulum, frontal recess, middle turbinate and optic nerve were assessed as: clearly demonstrated (2 points); demonstrated but not clearly visualized (1 point); or not seen (0 points). No significant difference was shown between any of the four groups in terms of image quality according to the scoring system used in this study. Mean radiation dose to the orbit was reduced by 77%, from 13.5 mGy at 200 mAs to 3.1 mGy at 50 mAs (p<0.05). CT of the sinuses can be performed in patients prior to FESS at greatly reduced mAs without loss of diagnostic quality of the images. This is important in reducing the radiation dose to the lens.

Entities:  

Mesh:

Year:  2001        PMID: 11718388     DOI: 10.1259/bjr.74.878.740157

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  Use of the lowest necessary radiation dose.

Authors:  Allan J Fox
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

2.  Data analysis of low dose multislice helical CT scan in orbital trauma.

Authors:  Ji-Wei Wang; Chong Tang; Bo-Rong Pan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

Review 4.  Radiological imaging of inflammatory lesions in the nasal cavity and paranasal sinuses.

Authors:  H B Eggesbø
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

5.  Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis.

Authors:  Marcin Fraczek; Maciej Guzinski; Monika Morawska-Kochman; Kamil H Nelke; Tomasz Krecicki
Journal:  Dentomaxillofac Radiol       Date:  2016-10-17       Impact factor: 2.419

6.  Investigation of an optimized scanning protocol for the dentomaxillofacial region using 320-slice multidetector computed tomography.

Authors:  Wei-Chan Lin; Hsueh-Han Wang; Wen-Lin Hsu; Bi-Hui Cao; De-Ji Chen; Chia-Jung Tsai
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

7.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

8.  Impact of prone, supine and oblique patient positioning on CBCT image quality, contrast-to-noise ratio and figure of merit value in the maxillofacial region.

Authors:  Juha Koivisto; Maureen van Eijnatten; Jorma Järnstedt; Kirsi Holli-Helenius; Prasun Dastidar; Jan Wolff
Journal:  Dentomaxillofac Radiol       Date:  2017-04-07       Impact factor: 2.419

9.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

10.  Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

Authors:  C Leiva-Salinas; L Flors; P Gras; F Más-Estellés; P Lemercier; J T Patrie; M Wintermark; L Martí-Bonmatí
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-26       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.