Literature DB >> 15778838

Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Birgit B Ertl-Wagner1, Roland Bruening, Jeffrey Blume, Ralf-Thorsten Hoffmann, Brad Snyder, Karin A Herrmann, Maximilian F Reiser.   

Abstract

The aim of this prospective, multireader trial was to investigate image quality and vascular delineation of cranial multislice CT angiography (MSCTA) to identify strengths and weaknesses of the method. Sixty consecutive patients underwent standardized cranial MSCTA. The mean estimated effective dose was 0.96+/-0.11 mSv. Three masked readers independently graded image quality parameters and vascular delineation on a 5-point scale. Vascular attenuation values and dose-length products were assessed quantitatively. Quantitative parameters were evaluated with a proportional odds regression model with bootstrapped standard errors to adjust the relevant standard errors for correlation within subjects and across readers. The non-parametric Wilcoxon sign-rank test was applied for quantitative measurements. Good to excellent ratings were observed regarding image quality parameters and vascular delineation. The delineation of veins was rated higher than that of arteries (OR 2.00). Smaller arterial segments were rated significantly less favorably than larger segments (OR up to 26.98). Moreover, the cavernous sinus, the C2 segment of the ICA and the communicating arteries demonstrated lower scores. Attenuation values were >240 HU and vessel-to-parenchyma ratios >7 in all vessels. Cranial MSCTA achieved high ratings regarding image quality and vascular delineation. Relative weaknesses were found in small arterial subsegments and in vessels in close topographical proximity to bone.

Entities:  

Mesh:

Year:  2005        PMID: 15778838     DOI: 10.1007/s00330-005-2689-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  31 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

2.  CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study.

Authors:  H W Venema; F J Hulsmans; G J den Heeten
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

3.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA.

Authors:  Yoshimasa Imanishi; Atsushi Fukui; Hiroshi Niimi; Daisuke Itoh; Kyouko Nozaki; Shunsuke Nakaji; Kumiko Ishizuka; Hitoshi Tabata; Yu Furuya; Masahiko Uzura; Hideto Takahama; Suzuo Hashizume; Shiro Arima; Yasuo Nakajima
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

4.  Evaluation of section sensitivity profiles and image noise in spiral CT.

Authors:  A Polacin; W A Kalender; G Marchal
Journal:  Radiology       Date:  1992-10       Impact factor: 11.105

5.  Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination.

Authors:  Marcel van Straten; Henk W Venema; Geert J Streekstra; Charles B L M Majoie; Gerard J den Heeten; Cornelis A Grimbergen
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

6.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

7.  The effect of decreasing mAs on image quality and patient dose in sinus CT.

Authors:  S A Sohaib; P D Peppercorn; J A Horrocks; M H Keene; G S Kenyon; R H Reznek
Journal:  Br J Radiol       Date:  2001-02       Impact factor: 3.039

8.  Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis?

Authors:  B Ghaye; D Szapiro; I Mastora; V Delannoy; A Duhamel; J Remy; M Remy-Jardin
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

9.  Relationships between physical dose quantities and patient dose in CT.

Authors:  N Hidajat; J Mäurer; R J Schröder; A Nunnemann; M Wolf; K Pauli; R Felix
Journal:  Br J Radiol       Date:  1999-06       Impact factor: 3.039

10.  Relationship between intracranial pressure and the development of vasospasm after aneurysmal subarachnoid hemorrhage.

Authors:  T Fukuhara; C M Douville; J P Eliott; D W Newell; H R Winn
Journal:  Neurol Med Chir (Tokyo)       Date:  1998-11       Impact factor: 1.742

View more
  3 in total

1.  Application of MSCTA combined with VRT in the operation of cervical dumbbell tumors.

Authors:  Wan Wang; Jia Lin; Engelbert Knosp; Yuanzheng Zhao; Dianhui Xiu; Yongchuan Guo
Journal:  Int J Clin Exp Med       Date:  2015-08-15

2.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

3.  Diagnostic value of multidetector-row CT angiography in the evaluation of thrombosis of the cerebral venous sinuses.

Authors:  J Linn; B Ertl-Wagner; K C Seelos; M Strupp; M Reiser; H Brückmann; R Brüning
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.