Literature DB >> 11465464

Consistent image registration.

G E Christensen1, H J Johnson.   

Abstract

This paper presents a new method for image registration based on jointly estimating the forward and reverse transformations between two images while constraining these transforms to be inverses of one another. This approach produces a consistent set of transformations that have less pairwise registration error, i.e., better correspondence, than traditional methods that estimate the forward and reverse transformations independently. The transformations are estimated iteratively and are restricted to preserve topology by constraining them to obey the laws of continuum mechanics. The transformations are parameterized by a Fourier series to diagonalize the covariance structure imposed by the continuum mechanics constraints and to provide a computationally efficient numerical implementation. Results using a linear elastic material constraint are presented using both magnetic resonance and X-ray computed tomography image data. The results show that the joint estimation of a consistent set of forward and reverse transformations constrained by linear-elasticity give better registration results than using either constraint alone or none at all.

Mesh:

Year:  2001        PMID: 11465464     DOI: 10.1109/42.932742

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  116 in total

1.  Assessing the intrinsic precision of 3D/3D rigid image registration results for patient setup in the absence of a ground truth.

Authors:  Jian Wu; Martin J Murphy
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Fast tensor image morphing for elastic registration.

Authors:  Pew-Thian Yap; Guorong Wu; Hongtu Zhu; Weili Lin; Dinggang Shen
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

3.  Analysis of deformable image registration accuracy using computational modeling.

Authors:  Hualiang Zhong; Jinkoo Kim; Indrin J Chetty
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

4.  A pseudoinverse deformation vector field generator and its applications.

Authors:  C Yan; H Zhong; M Murphy; E Weiss; J V Siebers
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

5.  4DCT-based measurement of changes in pulmonary function following a course of radiation therapy.

Authors:  Kai Ding; John E Bayouth; John M Buatti; Gary E Christensen; Joseph M Reinhardt
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  LANDMARK MATCHING ON THE SPHERE USING DISTANCE FUNCTIONS.

Authors:  Natasha Leporé; Alex Leow; Paul Thompson
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2006-04

7.  Consistency-based rectification of nonrigid registrations.

Authors:  Tobias Gass; Gábor Székely; Orcun Goksel
Journal:  J Med Imaging (Bellingham)       Date:  2015-03-25

8.  Validation of a nonrigid registration error detection algorithm using clinical MRI brain data.

Authors:  Ryan D Datteri; Yuan Liu; Pierre-Francois D'Haese; Benoit M Dawant
Journal:  IEEE Trans Med Imaging       Date:  2014-07-30       Impact factor: 10.048

9.  Iterative inversion of deformation vector fields with feedback control.

Authors:  Abhishek Dubey; Alexandros-Stavros Iliopoulos; Xiaobai Sun; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2018-06-10       Impact factor: 4.071

10.  Surface fluid registration of conformal representation: application to detect disease burden and genetic influence on hippocampus.

Authors:  Jie Shi; Paul M Thompson; Boris Gutman; Yalin Wang
Journal:  Neuroimage       Date:  2013-04-13       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.