Consistency-based rectification of nonrigid registrations.

Tobias Gass1, Gábor Székely1, Orcun Goksel1.   

Abstract

We present a technique to rectify nonrigid registrations by improving their group-wise consistency, which is a widely used unsupervised measure to assess pair-wise registration quality. While pair-wise registration methods cannot guarantee any group-wise consistency, group-wise approaches typically enforce perfect consistency by registering all images to a common reference. However, errors in individual registrations to the reference then propagate, distorting the mean and accumulating in the pair-wise registrations inferred via the reference. Furthermore, the assumption that perfect correspondences exist is not always true, e.g., for interpatient registration. The proposed consistency-based registration rectification (CBRR) method addresses these issues by minimizing the group-wise inconsistency of all pair-wise registrations using a regularized least-squares algorithm. The regularization controls the adherence to the original registration, which is additionally weighted by the local postregistration similarity. This allows CBRR to adaptively improve consistency while locally preserving accurate pair-wise registrations. We show that the resulting registrations are not only more consistent, but also have lower average transformation error when compared to known transformations in simulated data. On clinical data, we show improvements of up to 50% target registration error in breathing motion estimation from four-dimensional MRI and improvements in atlas-based segmentation quality of up to 65% in terms of mean surface distance in three-dimensional (3-D) CT. Such improvement was observed consistently using different registration algorithms, dimensionality (two-dimensional/3-D), and modalities (MRI/CT).

Keywords:  consistency; group-wise registration; least-squares; nonrigid registration; registration circuits

Year:  2015        PMID: 26158083      PMCID: PMC4478936          DOI: 10.1117/1.JMI.2.1.014005

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  22 in total

1.  Voxel similarity measures for 3-D serial MR brain image registration.

Authors:  M Holden; D L Hill; E R Denton; J M Jarosz; T C Cox; T Rohlfing; J Goodey; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  2000-02       Impact factor: 10.048

2.  Fundamental performance limits in image registration.

Authors:  Dirk Robinson; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-09       Impact factor: 10.856

3.  Performance evaluation of grid-enabled registration algorithms using bronze-standards.

Authors:  Tristan Glatard; Xavier Pennec; Johan Montagnat
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

4.  Transitive inverse-consistent manifold registration.

Authors:  Xiujuan Geng; Dinesh Kumar; Gary E Christensen
Journal:  Inf Process Med Imaging       Date:  2005

5.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

6.  Bootstrap resampling for image registration uncertainty estimation without ground truth.

Authors:  Jan Kybic
Journal:  IEEE Trans Image Process       Date:  2010-01       Impact factor: 10.856

7.  Automated image registration: I. General methods and intrasubject, intramodality validation.

Authors:  R P Woods; S T Grafton; C J Holmes; S R Cherry; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1998 Jan-Feb       Impact factor: 1.826

8.  A Bayesian approach for spatially adaptive regularisation in non-rigid registration.

Authors:  Ivor J A Simpson; Mark W Woolrich; Manuel Jorge Cardoso; David M Cash; Marc Modat; Julia A Schnabel; Sebastien Ourselin
Journal:  Med Image Comput Comput Assist Interv       Date:  2013

9.  Bayesian characterization of uncertainty in intra-subject non-rigid registration.

Authors:  Petter Risholm; Firdaus Janoos; Isaiah Norton; Alex J Golby; William M Wells
Journal:  Med Image Anal       Date:  2013-03-14       Impact factor: 8.545

10.  Diffeomorphic registration using B-splines.

Authors:  Daniel Rueckert; Paul Aljabar; Rolf A Heckemann; Joseph V Hajnal; Alexander Hammers
Journal:  Med Image Comput Comput Assist Interv       Date:  2006
View more
  2 in total

1.  Rapid Quality Assessment of Nonrigid Image Registration Based on Supervised Learning.

Authors:  Eung-Joo Lee; William Plishker; Nobuhiko Hata; Paul B Shyn; Stuart G Silverman; Shuvra S Bhattacharyya; Raj Shekhar
Journal:  J Digit Imaging       Date:  2021-10-13       Impact factor: 4.903

2.  Learning a Metric for Multimodal Medical Image Registration without Supervision Based on Cycle Constraints.

Authors:  Hanna Siebert; Lasse Hansen; Mattias P Heinrich
Journal:  Sensors (Basel)       Date:  2022-02-01       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.