Literature DB >> 20632561

Assessing the intrinsic precision of 3D/3D rigid image registration results for patient setup in the absence of a ground truth.

Jian Wu1, Martin J Murphy.   

Abstract

PURPOSE: To assess the precision and robustness of patient setup corrections computed from 3D/3D rigid registration methods using image intensity, when no ground truth validation is possible.
METHODS: Fifteen pairs of male pelvic CTs were rigidly registered using four different in-house registration methods. Registration results were compared for different resolutions and image content by varying the image down-sampling ratio and by thresholding out soft tissue to isolate bony landmarks. Intrinsic registration precision was investigated by comparing the different methods and by reversing the source and the target roles of the two images being registered.
RESULTS: The translational reversibility errors for successful registrations ranged from 0.0 to 1.69 mm. Rotations were less than 1 degrees. Mutual information failed in most registrations that used only bony landmarks. The magnitude of the reversibility error was strongly correlated with the success/ failure of each algorithm to find the global minimum.
CONCLUSIONS: Rigid image registrations have an intrinsic uncertainty and robustness that depends on the imaging modality, the registration algorithm, the image resolution, and the image content. In the absence of an absolute ground truth, the variation in the shifts calculated by several different methods provides a useful estimate of that uncertainty. The difference observed by reversing the source and target images can be used as an indication of robust convergence.

Entities:  

Mesh:

Year:  2010        PMID: 20632561      PMCID: PMC2881924          DOI: 10.1118/1.3414041

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Megavoltage CT on a tomotherapy system.

Authors:  K J Ruchala; G H Olivera; E A Schloesser; T R Mackie
Journal:  Phys Med Biol       Date:  1999-10       Impact factor: 3.609

3.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

Authors:  D A Jaffray; J H Siewerdsen
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

Review 4.  Mutual-information-based registration of medical images: a survey.

Authors:  Josien P W Pluim; J B Antoine Maintz; Max A Viergever
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

5.  Evaluation of similarity measures for reconstruction-based registration in image-guided radiotherapy and surgery.

Authors:  Darko Skerl; Dejan Tomazevic; Bostjan Likar; Franjo Pernus
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-01       Impact factor: 7.038

6.  Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy.

Authors:  Jian Wu; Minho Kim; Jorg Peters; Heeteak Chung; Sanjiv S Samant
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

7.  Comparative evaluation of similarity measures for the rigid registration of multi-modal head images.

Authors:  Darko Skerl; Bostjan Likar; J Michael Fitzpatrick; Franjo Pernus
Journal:  Phys Med Biol       Date:  2007-09-03       Impact factor: 3.609

8.  A comparison of similarity measures for use in 2-D-3-D medical image registration.

Authors:  G P Penney; J Weese; J A Little; P Desmedt; D L Hill; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

9.  Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study.

Authors:  Laurence E Court; Lei Dong; Noah Taylor; Matthew Ballo; Kei Kitamura; Andrew K Lee; Jennifer O'Daniel; R Allen White; Rex Cheung; Deborah Kuban
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-06-01       Impact factor: 7.038

10.  How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?

Authors:  Martin J Murphy; Zhouping Wei; Mirek Fatyga; Jeffrey Williamson; Mitchell Anscher; Timothy Wallace; Elizabeth Weiss
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

View more
  3 in total

1.  A digitally reconstructed radiograph algorithm calculated from first principles.

Authors:  David Staub; Martin J Murphy
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

2.  A neural network based 3D/3D image registration quality evaluator for the head-and-neck patient setup in the absence of a ground truth.

Authors:  Jian Wu; Martin J Murphy
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  Comparisons of multiple automated anatomy-based image-guidance methods for patient setup before head/neck external beam radiotherapy.

Authors:  Nesrin Dogan; Shiyu Song; Habeeb Saleh; Jian Wu; Martin J Murphy
Journal:  J Appl Clin Med Phys       Date:  2010-10-13       Impact factor: 2.102