Literature DB >> 11451106

Total condylar knee replacement: a 20-year followup study.

J A Rodriguez1, H Bhende, C S Ranawat.   

Abstract

Between 1976 and 1979, 220 total knee replacements were done on 164 patients using the Total Condylar Knee replacement. The diagnosis was rheumatoid arthritis in 111 knees and osteoarthritis in 109 knees. Patients with 157 knees are known to have died as of December 1998, leaving 63 knees in patients who are still alive. Twelve patients with 18 knees were lost to followup. The average 20-year followup data (range, 18-22 years) are presented for 45 knees in 30 patients using Knee Society evaluations. The average Knee Society clinical score for the surviving patients was 88 points, and the average functional score was 58 points. The radiographic followup averaged 19 years. The average overall alignment was 3 degrees valgus. Femoral lucencies were present in 17 of 40 adequate lateral views, most commonly about the anterior and posterior surfaces. Two femoral components were loose. Twenty-two tibial components had radiolucencies; four radiolucencies were circumferential. The remaining 41 knees retained a well-fixed cemented central peg despite proximal interface lucencies. From the group of 220 knees, 14 revisions have been done at an average of 11.4 years postoperative. Two knee replacements were revised for isolated tibial loosening, whereas one knee replacement had isolated femoral loosening. Three knee replacements were revised for loosening of both components, and one was revised for isolated patellar loosening. Four patients had sepsis develop; three of these four patients were treated with two-stage revision, and one underwent fusion. Three patients were treated for supracondylar fractures. The Total Condylar Knee replacement maintains excellent durability at 20-years followup.

Entities:  

Mesh:

Year:  2001        PMID: 11451106

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  67 in total

1.  [CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study].

Authors:  H Bäthis; L Perlick; C Lüring; T Kalteis; J Grifka
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA.

Authors:  Eun-Kyoo Song; Jong-Keun Seon; Ji-Hyeon Yim; Nathan A Netravali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

Authors:  John J Callaghan; Mitchell W Beckert; David W Hennessy; Devon D Goetz; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

4.  Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.

Authors:  Namık Sahin; Teoman Atıcı; Ünal Kurtoğlu; Ali Turgut; Güven Ozkaya; Yüksel Ozkan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-03       Impact factor: 4.342

5.  No early tibial tray loosening after surface cementing technique in mobile-bearing TKA.

Authors:  Roberto Rossi; Matteo Bruzzone; Davide Edoardo Bonasia; Andrea Ferro; Filippo Castoldi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

6.  Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

Authors:  James W Pritchett
Journal:  Clin Orthop Relat Res       Date:  2015-02-27       Impact factor: 4.176

7.  Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?

Authors:  Markus Tingart; Christian Lüring; Holger Bäthis; Johannes Beckmann; Joachim Grifka; Lars Perlick
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-09-26       Impact factor: 4.342

8.  International multi-centre survivorship analysis of mobile bearing total knee arthroplasty.

Authors:  James B Stiehl; Karel J Hamelynck; Paul E Voorhorst
Journal:  Int Orthop       Date:  2006-03-18       Impact factor: 3.075

9.  Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Hoser; Sebastian Quirbach; Rene Attal; Alfred Hennerbichler; Christian Fink
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

10.  Changes in hindfoot alignment after total knee arthroplasty in knee osteoarthritic patients with varus deformity.

Authors:  Woo-Shin Cho; Hun-Sik Cho; Seong-Eun Byun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-16       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.