PURPOSE: The purpose of the present study was to determine whether the axes aligned with the sulcus between the tibial spines and the middle of the posterior cruciate ligament at the knee and with the tibialis anterior tendon at the ankle provide a neutral rotational and coronal alignment of the tibial component in total knee arthroplasty (TKA).
METHODS: In a cohort of 45 TKA patients, CT scans were taken to quantify coronal and rotational positioning of the components. All patients received a posterior stabilised total knee replacement with a fixed insert (PFC Sigma; DePuy Orthopaedics, Inc; Warsaw, IN, USA). The tibial guide was aligned with the sulcus between the tibial spines and the middle of the posterior cruciate ligament at the knee and with the tibialis anterior tendon at the ankle.
RESULTS: The average post-operative coronal mechanical alignment was 1° varus (range 4.5° varus-1.5° valgus; SD ±1.51). The average post-operative rotational deviation from the transepicondylar axes (TEA) was 0.78° of internal rotation (1.50° of internal rotation - 3.5° of external rotation) for the tibial component. The whole-extremity mechanical axis deviation was outside the tolerance range of 3° in 4 patients (8.9 %). Deviation of the tibial component rotational position relative to the TEA was 3° or less in 94.5 % of the patients.
CONCLUSIONS: When the tibial component is aligned using the axis drawn from the centre of the PCL to the sulcus between the tibial spines on the proximal tibia and to the tibialis anterior tendon at the ankle, good alignment will be achieved in both the coronal and axial planes. LEVEL OF EVIDENCE: IV.

Entities:  

Mesh:

Year:  2012        PMID: 22751944     DOI: 10.1007/s00167-012-2120-5

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  32 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  An anteroposterior axis of the tibia for total knee arthroplasty.

Authors:  Masao Akagi; Masamichi Oh; Tohgo Nonaka; Harutoshi Tsujimoto; Taiyo Asano; Chiaki Hamanishi
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

3.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

4.  Reproducibility of measurement of femoral component rotation after total knee arthroplasty using computer tomography.

Authors:  Thomas Suter; Marco Zanetti; Marius Schmid; José Romero
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

5.  Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis.

Authors:  Paolo Aglietti; Lorenzo Sensi; Pierluigi Cuomo; Antonio Ciardullo
Journal:  Clin Orthop Relat Res       Date:  2008-09-30       Impact factor: 4.176

6.  Anterior border of the tibia as a landmark for extramedullary alignment guide in total knee arthroplasty for varus knees.

Authors:  Shingo Fukagawa; Shuichi Matsuda; Hiroaki Mitsuyasu; Hiromasa Miura; Ken Okazaki; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  J Orthop Res       Date:  2011-01-21       Impact factor: 3.494

7.  Variability of extraarticular tibial rotation references for total knee arthroplasty.

Authors:  Masao Akagi; Shigeshi Mori; Shunji Nishimura; Akio Nishimura; Taiyo Asano; Chiaki Hamanishi
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

8.  Mechanisms of failure in total knee arthroplasty.

Authors:  J R Moreland
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

9.  Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees.

Authors:  N Yoshino; S Takai; Y Ohtsuki; Y Hirasawa
Journal:  J Arthroplasty       Date:  2001-06       Impact factor: 4.757

10.  Malrotation causing patellofemoral complications after total knee arthroplasty.

Authors:  R A Berger; L S Crossett; J J Jacobs; H E Rubash
Journal:  Clin Orthop Relat Res       Date:  1998-11       Impact factor: 4.176

View more
  7 in total

1.  Medial sixth of the patellar tendon at the tibial attachment is useful for the anterior reference in rotational alignment of the tibial component.

Authors:  Shinya Kawahara; Ken Okazaki; Shuichi Matsuda; Hiroaki Mitsuyasu; Hiroyuki Nakahara; Shigetoshi Okamoto; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-12       Impact factor: 4.342

2.  The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA).

Authors:  Michael Drexler; David Backstein; Ueli Studler; Dror Lakstein; Barak Haviv; Ran Schwarzkopf; Tal Frenkel Rutenberg; Yaniv Warschawski; Ehud Rath; Yona Kosashvili
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-26       Impact factor: 4.342

3.  Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle-trochlear groove can be an aid.

Authors:  He Zhang; Chengming Cao; Han Zhang; Shoujiang Han
Journal:  J Orthop Surg Res       Date:  2022-05-04       Impact factor: 2.677

4.  Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration.

Authors:  Pei-Hui Wu; Zhi-Qi Zhang; Shu-Ying Fang; Zi-Bo Yang; Yan Kang; Ming Fu; Wei-Ming Liao
Journal:  Chin Med J (Engl)       Date:  2016-11-05       Impact factor: 2.628

5.  Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty.

Authors:  Joong Il Kim; Jak Jang; Ki Woong Lee; Hyuk Soo Han; Sahnghoon Lee; Myung Chul Lee
Journal:  BMC Musculoskelet Disord       Date:  2017-06-12       Impact factor: 2.362

6.  Three-point Method to Guide the Tibial Resection and Component Placing in Total Knee Arthroplasty.

Authors:  Ming-Yang Liu; Hai-Bo Wang; Shi-Wei Liu; Guan-Peng Zhang; Jian-Guo Liu; Chen Yang
Journal:  Orthop Surg       Date:  2020-06       Impact factor: 2.071

7.  The medial tangent of the proximal tibia is a suitable extra-articular landmark in determining the tibial anteroposterior axis.

Authors:  Hyunho Lee; Takanobu Sumino; Takashi Suzuki; Yutaka Sano; Noriyuki Endo; Yingshih Chang; Hirohisa Fujimaki; Keinosuke Ryu; Kazuyoshi Nakanishi
Journal:  BMC Musculoskelet Disord       Date:  2021-04-12       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.