Literature DB >> 16547718

International multi-centre survivorship analysis of mobile bearing total knee arthroplasty.

James B Stiehl1, Karel J Hamelynck, Paul E Voorhorst.   

Abstract

We retrospectively reviewed the experience of a large international multi-centre study of primary total knee arthroplasty with mobile bearing design and modifications of the tibial component to allow for bicruciate preservation, posterior cruciate retention, or sacrifice. Twenty-seven surgeons performed 4,743 total knee replacements between 1981 and 1997. Implants inserted were 324 that retained both cruciate ligaments, 2,165 that retained the posterior cruciate, and 2,254 that sacrificed both cruciates. The patella was resurfaced in 2,838 and unresurfaced in 1,905. With failure defined as revision or reoperation for any reason, the overall survivorship was 79% at 16 years' follow-up. Revision occurred in 259 (5.4%) knees out of the entire cohort. The risk adjusted rates of failure were higher in females, younger patients, osteoarthritis, post-traumatic arthritis, and in patients who had a meniscal bearing prosthesis or patellar resurfacing. The most common cause of revision was bearing-related issues including chronic instability, bearing subluxation, bearing dislocation, or bearing wear in 2.3%.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16547718      PMCID: PMC2532087          DOI: 10.1007/s00264-005-0053-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  61 in total

1.  Kinematic total knee arthroplasty: a 10- to 14-year prospective follow-up review.

Authors:  F C Ewald; R J Wright; R Poss; W H Thomas; M D Mason; C B Sledge
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

2.  The Genesis total knee prosthesis: a 10-year followup study.

Authors:  R S Laskin
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

3.  Twenty-year evaluation of the New Jersey LCS Rotating Platform Knee Replacement.

Authors:  Frederick F Buechel; Frederick F Buechel; Michael J Pappas; Jerry Dalessio
Journal:  J Knee Surg       Date:  2002       Impact factor: 2.757

4.  A comparison of four models of total knee-replacement prostheses.

Authors:  J N Insall; C S Ranawat; P Aglietti; J Shine
Journal:  J Bone Joint Surg Am       Date:  1976-09       Impact factor: 5.284

5.  Twelve years' experience with posterior cruciate-retaining total knee arthroplasty.

Authors:  R D Scott; T B Volatile
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

6.  Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis.

Authors:  J W Goodfellow; J O'Connor
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

7.  The problem of surface damage in polyethylene total knee components.

Authors:  T M Wright; D L Bartel
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

8.  The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997.

Authors:  O Robertsson; K Knutson; S Lewold; L Lidgren
Journal:  Acta Orthop Scand       Date:  2001-10

9.  Long-term followup of the Miller-Galante total knee replacement.

Authors:  R A Berger; A G Rosenberg; R M Barden; M B Sheinkop; J J Jacobs; J O Galante
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

10.  The mechanics of the knee and prosthesis design.

Authors:  J Goodfellow; J O'Connor
Journal:  J Bone Joint Surg Br       Date:  1978-08
View more
  9 in total

1.  Single-radius, multidirectional total knee replacement.

Authors:  Jean-Yves Jenny; Rolf Miehlke; Dominique Saragaglia; Robert Geyer; Numa Mercier; Jean-Yves Schoenahl; Birger Thiel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-28       Impact factor: 4.342

2.  Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after five years minimum.

Authors:  Jung-Ro Yoon; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2018-03-20       Impact factor: 3.075

3.  Unconstrained total knee arthroplasty in significant valgus deformity: a modified surgical technique to balance the knee and avoid instability.

Authors:  R Pagoti; S O'Brien; E Doran; D Beverland
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-28       Impact factor: 4.342

4.  No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty.

Authors:  Ruud P van Hove; Richard M Brohet; Barend J van Royen; Peter A Nolte
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-05       Impact factor: 4.342

5.  Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion ((®)) UC-TKA.

Authors:  Jean-Baptiste Chavoix
Journal:  Open Orthop J       Date:  2013-05-17

Review 6.  Risk factors for revision of total knee arthroplasty: a scoping review.

Authors:  L L Jasper; C A Jones; J Mollins; S L Pohar; L A Beaupre
Journal:  BMC Musculoskelet Disord       Date:  2016-04-26       Impact factor: 2.362

7.  Total knee arthroplasty for treatment of post-traumatic arthritis: Systematic review.

Authors:  Hesham Saleh; Stephen Yu; Jonathan Vigdorchik; Ran Schwarzkopf
Journal:  World J Orthop       Date:  2016-09-18

8.  Effects of pay for performance on risk incidence of infection and of revision after total knee arthroplasty in type 2 diabetic patients: A nationwide matched cohort study.

Authors:  Yi-Shiun Tsai; Pei-Tseng Kung; Ming-Chou Ku; Yeuh-Hsin Wang; Wen-Chen Tsai
Journal:  PLoS One       Date:  2018-11-02       Impact factor: 3.240

9.  The High Flex Total Knee Arthroplasty-Higher Incidence of Aseptic Loosening and No Benefit in Comparison to Conventional Total Knee Arthroplasty: Minimum 16-Years Follow-Up Results.

Authors:  Florian Radetzki; Alexander Zeh; Karl-Stefan Delank; David Wohlrab
Journal:  Indian J Orthop       Date:  2020-10-06       Impact factor: 1.251

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.