Literature DB >> 11403306

Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source.

J C Wolff1, C Eckers, A B Sage, K Giles, R Bateman.   

Abstract

A new electrospray dual sprayer, LockSpray, was developed for accurate mass measurements on a quadrupole orthogonal acceleration time-of-flight mass spectrometer (oa-Q-ToF). With the dual-sprayer ion source, both sprays are orthogonal to each other. A mechanism similar to the one employed on the multiplexed electrospray source (MUX) allows switching between reference and sample sprayer. The reference sprayer is optimized for low flow rates, whereas the sample sprayer is a conventional Z-spray type sprayer. Earlier work using a modified MUX ion source on an orthogonal acceleration time-of-flight instrument showed promising results. In this paper, examples obtained with the LockSpray, specifically designed for accurate mass measurements on an oa-Q-ToF, are presented. The examples include results obtained for the identification of impurities in drug substances such as cimetidine and rosiglitazone, using accurate mass tandem mass spectrometry in both positive and negative ion electrospray modes. Good mass accuracies, i.e., within 2 mDa of the theoretical value, were obtained in MS and MS/MS operation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11403306     DOI: 10.1021/ac001419a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  14 in total

1.  Intercomparison study on accurate mass measurement of small molecules in mass spectrometry.

Authors:  Anthony W T Bristow; Kenneth S Webb
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

2.  Direct infusion electrospray ionization-ion mobility high resolution mass spectrometry (DIESI-IM-HRMS) for rapid characterization of potential bioprocess streams.

Authors:  Sharon M Munisamy; C Kevin Chambliss; Christopher Becker
Journal:  J Am Soc Mass Spectrom       Date:  2012-05-17       Impact factor: 3.109

3.  Correction of accurate mass measurement for target compound verification by quadrupole time-of-flight mass spectrometry.

Authors:  Harald C Köfeler; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

Review 4.  Biomarkers for neuroAIDS: the widening scope of metabolomics.

Authors:  Gurudutt Pendyala; Elizabeth J Want; William Webb; Gary Siuzdak; Howard S Fox
Journal:  J Neuroimmune Pharmacol       Date:  2006-10-10       Impact factor: 4.147

5.  Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation.

Authors:  Nicolas L Young; Michael C Sisto; Meggie N Young; Patrick G Grant; David W Killilea; LaTasha LaMotte; Kuang Jen J Wu; Carlito B Lebrilla
Journal:  Anal Chem       Date:  2007-07-06       Impact factor: 6.986

6.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia Ibrahim; Mikhail E Belov; Aleksey V Tolmachev; David C Prior; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-13       Impact factor: 6.986

7.  Induced dual-nanospray: a novel internal calibration method for convenient and accurate mass measurement.

Authors:  Yafeng Li; Ning Zhang; Yueming Zhou; Jianing Wang; Yiming Zhang; Jiyun Wang; Caiqiao Xiong; Suming Chen; Zongxiu Nie
Journal:  J Am Soc Mass Spectrom       Date:  2013-09       Impact factor: 3.109

8.  On the benefits of acquiring peptide fragment ions at high measured mass accuracy.

Authors:  Alexander Scherl; Scott A Shaffer; Gregory K Taylor; Patricia Hernandez; Ron D Appel; Pierre-Alain Binz; David R Goodlett
Journal:  J Am Soc Mass Spectrom       Date:  2008-03-04       Impact factor: 3.109

9.  Validation of LC-TOF-MS screening for drugs, metabolites, and collateral compounds in forensic toxicology specimens.

Authors:  Fessessework Guale; Shahriar Shahreza; Jeffrey P Walterscheid; Hsin-Hung Chen; Crystal Arndt; Anna T Kelly; Ashraf Mozayani
Journal:  J Anal Toxicol       Date:  2012-11-01       Impact factor: 3.367

10.  Ion-neutral Clustering of Bile Acids in Electrospray Ionization Across UPLC Flow Regimes.

Authors:  Patrick Brophy; Corey D Broeckling; James Murphy; Jessica E Prenni
Journal:  J Am Soc Mass Spectrom       Date:  2018-02-09       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.