Literature DB >> 23797862

Induced dual-nanospray: a novel internal calibration method for convenient and accurate mass measurement.

Yafeng Li1, Ning Zhang, Yueming Zhou, Jianing Wang, Yiming Zhang, Jiyun Wang, Caiqiao Xiong, Suming Chen, Zongxiu Nie.   

Abstract

Accurate mass information is of great importance in the determination of unknown compounds. An effective and easy-to-control internal mass calibration method will dramatically benefit accurate mass measurement. Here we reported a simple induced dual-nanospray internal calibration device which has the following three advantages: (1) the two sprayers are in the same alternating current field; thus both reference ions and sample ions can be simultaneously generated and recorded. (2) It is very simple and can be easily assembled. Just two metal tubes, two nanosprayers, and an alternating current power supply are included. (3)With the low-flow-rate character and the versatility of nanoESI, this calibration method is capable of calibrating various samples, even untreated complex samples such as urine and other biological samples with small sample volumes. The calibration errors are around 1 ppm in positive ion mode and 3 ppm in negative ion mode with good repeatability. This new internal calibration method opens up new possibilities in the determination of unknown compounds, and it has great potential for the broad applications in biological and chemical analysis.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23797862     DOI: 10.1007/s13361-013-0670-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  22 in total

1.  Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry.

Authors:  L Jiang; M Moini
Journal:  Anal Chem       Date:  2000-01-01       Impact factor: 6.986

2.  Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching.

Authors:  K R Clauser; P Baker; A L Burlingame
Journal:  Anal Chem       Date:  1999-07-15       Impact factor: 6.986

3.  Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept.

Authors:  C Eckers; J C Wolff; N J Haskins; A B Sage; K Giles; R Bateman
Journal:  Anal Chem       Date:  2000-08-15       Impact factor: 6.986

4.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?

Authors:  Andrea Schmidt; Michael Karas; Thomas Dülcks
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

5.  Characterization of dielectric barrier electrospray ionization for mass spectrometric detection.

Authors:  Ann Kathrin Stark; Michael Schilling; Dirk Janasek; Joachim Franzke
Journal:  Anal Bioanal Chem       Date:  2010-05-02       Impact factor: 4.142

6.  Accurate mass measurement in nano-electrospray ionization mass spectrometry by alternate switching of high voltage between sample and reference sprayers.

Authors:  Yoshinori Satomi; Yoichiro Kudo; Kyoko Sasaki; Toshiharu Hase; Toshifumi Takao
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

7.  Electronic coupling and scaling effects during dielectric barrier electrospray ionization.

Authors:  A K Stark; C Meyer; T Kraehling; G Jestel; U Marggraf; M Schilling; D Janasek; J Franzke
Journal:  Anal Bioanal Chem       Date:  2011-02-26       Impact factor: 4.142

8.  Induced nanoelectrospray ionization for matrix-tolerant and high-throughput mass spectrometry.

Authors:  Guangming Huang; Guangtao Li; R Graham Cooks
Journal:  Angew Chem Int Ed Engl       Date:  2011-09-05       Impact factor: 15.336

9.  Electrostatic-spray ionization mass spectrometry.

Authors:  Liang Qiao; Romain Sartor; Natalia Gasilova; Yu Lu; Elena Tobolkina; Baohong Liu; Hubert H Girault
Journal:  Anal Chem       Date:  2012-08-20       Impact factor: 6.986

10.  Sub-part-per-million precursor and product mass accuracy for high-throughput proteomics on an electron transfer dissociation-enabled orbitrap mass spectrometer.

Authors:  Craig D Wenger; Graeme C McAlister; Qiangwei Xia; Joshua J Coon
Journal:  Mol Cell Proteomics       Date:  2010-02-02       Impact factor: 5.911

View more
  3 in total

1.  Coaxial Electrospray Ionization for the Study of Rapid In-source Chemistry.

Authors:  Brynn N Sundberg; Anthony F Lagalante
Journal:  J Am Soc Mass Spectrom       Date:  2018-06-13       Impact factor: 3.109

2.  Direct Analysis of Biofluids by Mass Spectrometry with Microfluidic Voltage-Assisted Liquid Desorption Electrospray Ionization.

Authors:  Xiangtang Li; Rui Xu; Xin Wei; Hankun Hu; Shulin Zhao; Yi-Ming Liu
Journal:  Anal Chem       Date:  2017-11-03       Impact factor: 6.986

3.  Multi-channel microfluidic chip coupling with mass spectrometry for simultaneous electro-sprays and extraction.

Authors:  Cilong Yu; Fei Tang; Xiang Qian; Yan Chen; Quan Yu; Kai Ni; Xiaohao Wang
Journal:  Sci Rep       Date:  2017-12-12       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.