Literature DB >> 18417358

On the benefits of acquiring peptide fragment ions at high measured mass accuracy.

Alexander Scherl1, Scott A Shaffer, Gregory K Taylor, Patricia Hernandez, Ron D Appel, Pierre-Alain Binz, David R Goodlett.   

Abstract

The advantages and disadvantages of acquiring tandem mass spectra by collision-induced dissociation (CID) of peptides in linear ion trap Fourier-transform hybrid instruments are described. These instruments offer the possibility to transfer fragment ions from the linear ion trap to the FT-based analyzer for analysis with both high resolution and high mass accuracy. In addition, performing CID during the transfer of ions from the linear ion trap (LTQ) to the FT analyzer is also possible in instruments containing an additional collision cell (i.e., the "C-trap" in the LTQ-Orbitrap), resulting in tandem mass spectra over the full m/z range and not limited by the ejection q value of the LTQ. Our results show that these scan modes have lower duty cycles than tandem mass spectra acquired in the LTQ with nominal mass resolution, and typically result in fewer peptide identifications during data-dependent analysis of complex samples. However, the higher measured mass accuracy and resolution provides more specificity and hence provides a lower false positive ratio for the same number of true positives during database search of peptide tandem mass spectra. In addition, the search for modified and unexpected peptides is greatly facilitated with this data acquisition mode. It is therefore concluded that acquisition of tandem mass spectral data with high measured mass accuracy and resolution is a competitive alternative to "classical" data acquisition strategies, especially in situations of complex searches from large databases, searches for modified peptides, or for peptides resulting from unspecific cleavages.

Mesh:

Substances:

Year:  2008        PMID: 18417358      PMCID: PMC2459323          DOI: 10.1016/j.jasms.2008.02.005

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  RADARS, a bioinformatics solution that automates proteome mass spectral analysis, optimises protein identification, and archives data in a relational database.

Authors:  Helen I Field; David Fenyö; Ronald C Beavis
Journal:  Proteomics       Date:  2002-01       Impact factor: 3.984

2.  Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry.

Authors:  M E Belov; M V Gorshkov; H R Udseth; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-12       Impact factor: 3.109

3.  Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept.

Authors:  C Eckers; J C Wolff; N J Haskins; A B Sage; K Giles; R Bateman
Journal:  Anal Chem       Date:  2000-08-15       Impact factor: 6.986

4.  Popitam: towards new heuristic strategies to improve protein identification from tandem mass spectrometry data.

Authors:  Patricia Hernandez; Robin Gras; Julien Frey; Ron D Appel
Journal:  Proteomics       Date:  2003-06       Impact factor: 3.984

5.  OLAV: towards high-throughput tandem mass spectrometry data identification.

Authors:  Jacques Colinge; Alexandre Masselot; Marc Giron; Thierry Dessingy; Jérôme Magnin
Journal:  Proteomics       Date:  2003-08       Impact factor: 3.984

6.  De novo sequencing, peptide composition analysis, and composition-based sequencing: a new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Bernhard Spengler
Journal:  J Am Soc Mass Spectrom       Date:  2004-05       Impact factor: 3.109

7.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

8.  The Orbitrap: a new mass spectrometer.

Authors:  Qizhi Hu; Robert J Noll; Hongyan Li; Alexander Makarov; Mark Hardman; R Graham Cooks
Journal:  J Mass Spectrom       Date:  2005-04       Impact factor: 1.982

9.  Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Oliver Lange; Stevan Horning
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

10.  Biomarker candidate identification in Yersinia pestis using organism-wide semiquantitative proteomics.

Authors:  Kim K Hixson; Joshua N Adkins; Scott E Baker; Ronald J Moore; Brett A Chromy; Richard D Smith; Sandra L McCutchen-Maloney; Mary S Lipton
Journal:  J Proteome Res       Date:  2006-11       Impact factor: 4.466

View more
  23 in total

1.  Structural and mechanistic Information on c(1) ion formation in collision-induced fragmentation of peptides.

Authors:  Dominic Winter; Joerg Seidler; Bettina Hahn; Wolf D Lehmann
Journal:  J Am Soc Mass Spectrom       Date:  2010-07-07       Impact factor: 3.109

2.  Non-direct sequence ions in the tandem mass spectrometry of protonated peptide amides--an energy-resolved study.

Authors:  Alex G Harrison; Cagdas Tasoglu; Talat Yalcin
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-06       Impact factor: 3.109

3.  Fragmentation reactions of methionine-containing protonated octapeptides and fragment ions therefrom: an energy-resolved study.

Authors:  Alex G Harrison
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-14       Impact factor: 3.109

4.  Precursor ion independent algorithm for top-down shotgun proteomics.

Authors:  Yihsuan S Tsai; Alexander Scherl; Jason L Shaw; C Logan MacKay; Scott A Shaffer; Patrick R R Langridge-Smith; David R Goodlett
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-13       Impact factor: 3.109

Review 5.  Fourier transform mass spectrometry.

Authors:  Michaela Scigelova; Martin Hornshaw; Anastassios Giannakopulos; Alexander Makarov
Journal:  Mol Cell Proteomics       Date:  2011-07       Impact factor: 5.911

6.  Combining high-energy C-trap dissociation and electron transfer dissociation for protein O-GlcNAc modification site assignment.

Authors:  Peng Zhao; Rosa Viner; Chin Fen Teo; Geert-Jan Boons; David Horn; Lance Wells
Journal:  J Proteome Res       Date:  2011-07-25       Impact factor: 4.466

7.  Tandem mass spectrometry investigation of ADP-ribosylated kemptide.

Authors:  Shawna M Hengel; Scott A Shaffer; Brook L Nunn; David R Goodlett
Journal:  J Am Soc Mass Spectrom       Date:  2008-11-17       Impact factor: 3.109

8.  Analysis of human C1q by combined bottom-up and top-down mass spectrometry: detailed mapping of post-translational modifications and insights into the C1r/C1s binding sites.

Authors:  Delphine Pflieger; Cédric Przybylski; Florence Gonnet; Jean-Pierre Le Caer; Thomas Lunardi; Gérard J Arlaud; Régis Daniel
Journal:  Mol Cell Proteomics       Date:  2009-12-14       Impact factor: 5.911

9.  Glycation isotopic labeling with 13C-reducing sugars for quantitative analysis of glycated proteins in human plasma.

Authors:  Feliciano Priego-Capote; Alexander Scherl; Markus Müller; Patrice Waridel; Frédérique Lisacek; Jean-Charles Sanchez
Journal:  Mol Cell Proteomics       Date:  2009-11-06       Impact factor: 5.911

10.  Tandem mass spectrometry with ultrahigh mass accuracy clarifies peptide identification by database retrieval.

Authors:  Michael T Boyne; Benjamin A Garcia; Mingxi Li; Leonid Zamdborg; Craig D Wenger; Shannee Babai; Neil L Kelleher
Journal:  J Proteome Res       Date:  2009-01       Impact factor: 4.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.