Literature DB >> 15734334

Correction of accurate mass measurement for target compound verification by quadrupole time-of-flight mass spectrometry.

Harald C Köfeler1, Michael L Gross.   

Abstract

The aim of this work is to evaluate quadrupole/time-of-flight (QTOF) mass spectrometry for simultaneous measurement of accurate mass and quantification of a target by using a stable isotopically labeled internal standard. Mixtures of caffeine and (13)C(3)-caffeine (internal standard) at different concentration ratios were analyzed by capillary HPLC/QTOF. A calibration plot for quantification is linear over a factor of 20. Without invoking any correction scheme, the mass accuracy seriously degraded when the ratio of the mass standard to the test compound was not unity. The accuracy could be restored to approximately 2 ppm by using a quadratic function to correct the measured mass as a function of the measured signal ratio of target and internal calibrant.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15734334     DOI: 10.1016/j.jasms.2004.11.022

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer.

Authors:  K F Blom
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

2.  Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source.

Authors:  J C Wolff; C Eckers; A B Sage; K Giles; R Bateman
Journal:  Anal Chem       Date:  2001-06-01       Impact factor: 6.986

3.  Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept.

Authors:  C Eckers; J C Wolff; N J Haskins; A B Sage; K Giles; R Bateman
Journal:  Anal Chem       Date:  2000-08-15       Impact factor: 6.986

4.  Exact mass measurement of product ions for the structural confirmation and identification of unknown compounds using a quadrupole time-of-flight spectrometer: a simplified approach using combined tandem mass spectrometric functions.

Authors:  Karine Clauwaert; Sofie Vande Casteele; Bart Sinnaeve; Dieter Deforce; Willy Lambert; Carlos Van Peteghem; Jan Van Bocxlaer
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

5.  Intercomparison study on accurate mass measurement of small molecules in mass spectrometry.

Authors:  Anthony W T Bristow; Kenneth S Webb
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

6.  Mass-Profile Monitoring in Trace Analysis: Identification of Polychlorodibenzothiophenes in Crab Tissues Collected from the Newark/Raritan Bay system.

Authors:  Z Cai; D E Giblin; V M Ramanujam; M L Gross; A Cristini
Journal:  Environ Sci Technol       Date:  1994-08-01       Impact factor: 9.028

7.  Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS.

Authors:  N Zhang; S T Fountain; H Bi; D T Rossi
Journal:  Anal Chem       Date:  2000-02-15       Impact factor: 6.986

8.  Method validation for the determination of tetrachlorodibenzodioxin at the low parts-per-trillion level.

Authors:  M L Gross; T Sun; P A Lyon; S F Wojinski; D R Hilker; A E Dupuy; R G Heath
Journal:  Anal Chem       Date:  1981-10       Impact factor: 6.986

Review 9.  Congener-specific determination of dioxins and related compounds by gas chromatography coupled to LRMS, HRMS, MS/MS and TOFMS.

Authors:  E Eljarrat; D Barceló
Journal:  J Mass Spectrom       Date:  2002-11       Impact factor: 1.982

10.  Extractionless method for the determination of urinary caffeine metabolites using high-performance liquid chromatography coupled with tandem mass spectrometry.

Authors:  Heiko Schneider; Lan Ma; Hansruedi Glatt
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2003-06-15       Impact factor: 3.205

View more
  4 in total

1.  Automated sub-ppm mass accuracy on an ESI-TOF for use with drug discovery compound libraries.

Authors:  Justin G Stroh; Christopher J Petucci; Scott J Brecker; Nelson Huang; James M Lau
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-16       Impact factor: 3.109

Review 2.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

3.  Elimination of systematic mass measurement errors in liquid chromatography-mass spectrometry based proteomics using regression models and a priori partial knowledge of the sample content.

Authors:  Vladislav A Petyuk; Navdeep Jaitly; Ronald J Moore; Jie Ding; Thomas O Metz; Keqi Tang; Matthew E Monroe; Aleksey V Tolmachev; Joshua N Adkins; Mikhail E Belov; Alan R Dabney; Wei-Jun Qian; David G Camp; Richard D Smith
Journal:  Anal Chem       Date:  2007-12-29       Impact factor: 6.986

4.  Identification of novel fluorochemicals in aqueous film-forming foams used by the US military.

Authors:  Benjamin J Place; Jennifer A Field
Journal:  Environ Sci Technol       Date:  2012-06-15       Impact factor: 9.028

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.