Literature DB >> 14989605

Multislice CT: technical principles and future trends.

Mathias Prokop1.   

Abstract

Multislice scanning has substantially improved the performance of CT scanners, and thus the relation between scan duration, available scan length, and spatial resolution along the patient axis (z-axis). Near-isotropic imaging of whole organ systems is already possible with 4-slice scanners, but only with 8- to 16-slice scanners can the scan duration be shortened as well. Reconstructing overlapping thin-section data ("secondary raw data set") provides the basis for image reconstruction in any desired plane. By using thick multiplanar reformation (MPR) techniques, image quality can be improved while keeping patient dose low. Using unfavorable scanning parameters, exposure dose can be substantially increased compared with single-slice scanning, but thick MPR and individual-dose modulation techniques can provide the basis for dose reduction. Low-kVp scanning, in particular, is useful in children and slim adults and is an excellent technique to improve image contrast in CT angiographic studies. Short spiral scans should be avoided with multislice CT since overranging (extra rotations at the beginning and end of the scan, used for data interpolation) can substantially increase patient dose. Future trends include the introduction of thinner detector rows, wider detector arrays, faster tube rotation, and area detectors than can also be used for fluoroscopy. Noise-reduction techniques and individual dose modulation will gain importance with higher isotropic resolution. Functional and perfusion imaging, as well as advanced image processing and computer-aided diagnosis programs, will add to the possibilities of the next generation of multislice CT scanners.

Entities:  

Mesh:

Year:  2003        PMID: 14989605     DOI: 10.1007/s00330-003-2178-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Performance evaluation of a multi-slice CT system.

Authors:  C H McCollough; F E Zink
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Spiral interpolation algorithms for multislice spiral CT--part II: measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system.

Authors:  T Fuchs; J Krause; S Schaller; T Flohr; W A Kalender
Journal:  IEEE Trans Med Imaging       Date:  2000-09       Impact factor: 10.048

3.  The n-PI-method for helical cone-beam CT.

Authors:  R Proksa; T Köhler; M Grass; J Timmer
Journal:  IEEE Trans Med Imaging       Date:  2000-09       Impact factor: 10.048

4.  Advanced single-slice rebinning in cone-beam spiral CT.

Authors:  M Kachelriess; S Schaller; W A Kalender
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

5.  Aorta and iliac arteries: single versus multiple detector-row helical CT angiography.

Authors:  G D Rubin; M C Shiau; A N Leung; S T Kee; L J Logan; M C Sofilos
Journal:  Radiology       Date:  2000-06       Impact factor: 11.105

6.  Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

Authors:  K Hittmair; D Fleischmann
Journal:  J Comput Assist Tomogr       Date:  2001 Mar-Apr       Impact factor: 1.826

Review 7.  Data explosion: the challenge of multidetector-row CT.

Authors:  G D Rubin
Journal:  Eur J Radiol       Date:  2000-11       Impact factor: 3.528

Review 8.  Search for isotropic resolution in CT from conventional through multiple-row detector.

Authors:  Mahadevappa Mahesh
Journal:  Radiographics       Date:  2002 Jul-Aug       Impact factor: 5.333

9.  Algorithm for image reconstruction in multi-slice helical CT.

Authors:  K Taguchi; H Aradate
Journal:  Med Phys       Date:  1998-04       Impact factor: 4.071

Review 10.  Contrast optimization and scan timing for single and multidetector-row computed tomography.

Authors:  James A Brink
Journal:  J Comput Assist Tomogr       Date:  2003 May-Jun       Impact factor: 1.826

View more
  15 in total

1.  Image quality and radiation exposure in 320-row temporal bone computed tomography.

Authors:  H C Bauknecht; E Siebert; A Dannenberg; G Bohner; C Jach; S Diekmann; C Scheurig; R Klingebiel
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

2.  Urinary calculi: improved detection and characterization with thin-slice multidetector CT.

Authors:  Etienne Ketelslegers; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2005-06-16       Impact factor: 5.315

3.  Image quality in CT perfusion imaging of the brain. The role of iodine concentration.

Authors:  Matthias König; Eva Bültmann; Lucas Bode-Schnurbus; Dirk Koenen; Eckhart Mielke; Lothar Heuser
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

4.  Multidetector CT (64 Slices) of the liver: examination techniques.

Authors:  Andrea Laghi
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

5.  On-the-fly generation of multiplanar reformation images independent of CT scanner type.

Authors:  Dong Kyun Jeong; Kyoung Ho Lee; Bo Hyoung Kim; Kil Joong Kim; Young Hoon Kim; Vasundhara Bajpai; Yeong Gil Shin
Journal:  J Digit Imaging       Date:  2007-03-24       Impact factor: 4.056

6.  Computed tomography enterography and magnetic resonance enterography: the future of small bowel imaging.

Authors:  Mark E Baker; David M Einstein; Joseph C Veniero
Journal:  Clin Colon Rectal Surg       Date:  2008-08

7.  Summation or axial slab average intensity projection of abdominal thin-section CT datasets: can they substitute for the primary reconstruction from raw projection data?

Authors:  Kyoung Ho Lee; Helen Hong; Seokyung Hahn; Bohyoung Kim; Kil Joong Kim; Young Hoon Kim
Journal:  J Digit Imaging       Date:  2007-09-06       Impact factor: 4.056

8.  Volumetric measurement for comparison of the accuracy between intraoperative CT and postoperative MR imaging in pituitary adenoma surgery.

Authors:  C-C Lee; S-T Lee; C-N Chang; P-C Pai; Y-L Chen; T-C Hsieh; C-C Chuang
Journal:  AJNR Am J Neuroradiol       Date:  2011-06-23       Impact factor: 3.825

9.  Detection of liver metastases under 2 cm: comparison of different acquisition protocols in four row multidetector-CT (MDCT).

Authors:  Amina Abdelmoumene; Patrick Chevallier; Marc Chalaron; Frédéric Schneider; Francis R Verdun; Phillipe Frascarolo; Reto Meuli; Pierre Schnyder; Alban Denys
Journal:  Eur Radiol       Date:  2005-05-03       Impact factor: 5.315

10.  Comparative study of single and multislice computed tomography for assessment of the mandibular canal.

Authors:  Adriana da Silva Ferreira Paes; Carla Ruffeil Moreira; Marcelo Augusto Oliveira Sales; Marcelo Gusmão Paraíso Cavalcanti
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.