Literature DB >> 26051836

In vitro comparison of implant- versus gingiva-supported removable dentures in anterior and posterior applications.

Martin Rosentritt1, Felix Heidtkamp1, Helmut Hösl2, Sebastian Hahnel1, Verena Preis3.   

Abstract

OBJECTIVES: Removable dentures with different denture teeth may provide different performance and resistance in implant and gingival situations, or anterior and posterior applications.
MATERIALS AND METHODS: Two situations of removable dentures were investigated: gingiva (flexible) and implant (rigid) bearing. For simulating the gingiva/jaw situation, the dentures were supported with flexible lining material. For the implant situation, implants (d = 4.1 mm) were screwed into polymethylenmethacrylate (PMMA) resin. Two commercial (Vita-Physiodens MRP, SR Vivodent/Orthotyp DCL) and two experimental materials (EXP1, EXP2) were investigated in anterior (A) and posterior (P) tooth locations. Chewing simulation was performed, and failures were analyzed (microscopy, SEM). Fracture strength of surviving dentures was determined.
RESULTS: Only EXP1 revealed failures during chewing simulation. Failures varied between anterior and posterior locations, and between implant (P:4x; A:7x) or gingiva (P:1x; A:2x) situations. Kaplan-Meier log-rank test revealed significant differences for implant situations (p < 0.002), but not for gingiva bearing (p > 0.093). Fracture testing in the implant situation provided significantly highest values for EXP2 (1476.4 ± 532.2 N) in posterior location, and for DCL (1575.4 ± 264.4 N) and EXP2 (1797.0 ± 604.2 N) in anterior location. For gingival bearing, significantly highest values were found for DCL/P (2148.3 ± 836.3 N), and significantly lowest results for EXP1/A (308.2 ± 115.6 N). For EXP1 + EXP2 + Vita/P and for EXP1/A no significant differences were found between implant- or gingiva-supported situations.
CONCLUSIONS: Anterior and posterior teeth showed different material-dependent in vitro performance, further influenced by implant/gingiva bearing. While an implant in anterior application increased fracture strength of two materials, it decreased fracture values of 3/4 of the materials in posterior application. CLINICAL RELEVANCE: Survival of denture teeth may be influenced by material, oral position, and bearing situation.

Entities:  

Keywords:  Anterior/posterior teeth; Chewing simulation; Denture teeth; Fracture resistance; Implant/gingiva bearing

Mesh:

Substances:

Year:  2015        PMID: 26051836     DOI: 10.1007/s00784-015-1502-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  23 in total

1.  Technical failure rates of double crown-retained removable partial dentures.

Authors:  M Behr; E Hofmann; M Rosentritt; R Lang; G Handel
Journal:  Clin Oral Investig       Date:  2000-06       Impact factor: 3.573

2.  Effect of surface treatments and cyclic loading on the bond strength of acrylic resin denture teeth with autopolymerized repair acrylic resin.

Authors:  Graham K Meng; Kwok-Hung Chung; Madelyn L Fletcher-Stark; Hai Zhang
Journal:  J Prosthet Dent       Date:  2010-04       Impact factor: 3.426

3.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

4.  Evaluation of damage to removable dentures in two cities in Finland.

Authors:  P K Vallittu; V P Lassila; R Lappalainen
Journal:  Acta Odontol Scand       Date:  1993-12       Impact factor: 2.331

5.  In vitro wear resistance, hardness and elastic modulus of artificial denture teeth.

Authors:  Pii Suwannaroop; Pisaisit Chaijareenont; Natthavoot Koottathape; Hidekazu Takahashi; Mansuang Arksornnukit
Journal:  Dent Mater J       Date:  2011-07-21       Impact factor: 2.102

6.  Failure load of acrylic resin denture teeth bonded to high impact acrylic resins.

Authors:  D Barpal; D A Curtis; F Finzen; J Perry; S A Gansky
Journal:  J Prosthet Dent       Date:  1998-12       Impact factor: 3.426

7.  Approach for valuating the significance of laboratory simulation.

Authors:  Martin Rosentritt; Georgios Siavikis; Michael Behr; Carola Kolbeck; Gerhard Handel
Journal:  J Dent       Date:  2008-10-09       Impact factor: 4.379

8.  Bite force and oral function in patients with osseointegrated oral implants.

Authors:  T Haraldson; G E Carlsson
Journal:  Scand J Dent Res       Date:  1977-03

Review 9.  Survival analysis part I: basic concepts and first analyses.

Authors:  T G Clark; M J Bradburn; S B Love; D G Altman
Journal:  Br J Cancer       Date:  2003-07-21       Impact factor: 7.640

10.  In vitro wear resistance of three types of polymethyl methacrylate denture teeth.

Authors:  Katia Rodrigues Reis; Gerson Bonfante; Luiz Fernando Pegoraro; Paulo Cesar Rodrigues Conti; Pedro Cesar Garcia de Oliveira; Osvaldo Bazzan Kaizer
Journal:  J Appl Oral Sci       Date:  2008 May-Jun       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.