Literature DB >> 11021683

Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures.

K Wiesent1, K Barth, N Navab, P Durlak, T Brunner, O Schuetz, W Seissler.   

Abstract

Increasingly, three-dimensional (3-D) imaging technologies are used in medical diagnosis, for therapy planning, and during interventional procedures. We describe the possibilities of fast 3-D-reconstruction of high-contrast objects with high spatial resolution from only a small series of two-dimensional (2-D) planar radiographs. The special problems arising from the intended use of an open, mechanically unstable C-arm system are discussed. For the description of the irregular sampling geometry, homogeneous coordinates are used thoroughly. The well-known Feldkamp algorithm is modified to incorporate corresponding projection matrices without any decomposition into intrinsic and extrinsic parameters. Some approximations to speed up the whole reconstruction procedure and the tradeoff between image quality and computation time are also considered. Using standard hardware the reconstruction of a 256(3) cube is now possible within a few minutes, a time that is acceptable during interventions. Examples for cranial vessel imaging from some clinical test installations will be shown as well as promising results for bone imaging with a laboratory C-arm system.

Mesh:

Year:  2000        PMID: 11021683     DOI: 10.1109/42.870250

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  17 in total

1.  Three-dimensional rotational myelography.

Authors:  Markus Kufeld; Benjamin Claus; Adriana Campi; Wolfgang R Lanksch; Goetz Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2003-08       Impact factor: 3.825

2.  A phantom-based calibration method for digital x-ray tomosynthesis.

Authors:  Hui Miao; Xizeng Wu; Huijuan Zhao; Hong Liu
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

3.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

4.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

5.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

6.  Tomosynthesis via Total Variation Minimization Reconstruction and Prior Image Constrained Compressed Sensing (PICCS) on a C-arm System.

Authors:  Brian Nett; Jie Tang; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-03-18

Review 7.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

8.  Optimizing the Quality of 4D-DSA Temporal Information.

Authors:  K L Ruedinger; E C Harvey; S Schafer; M A Speidel; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-31       Impact factor: 3.825

9.  Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory.

Authors:  Stefan Hoppe; Joachim Hornegger; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-21       Impact factor: 2.924

10.  Accuracy of Voxel-Based and Algebraic Formula-Based Methods in Quantifying Cerebral Aneurysm Volume by 3D-Rotational Digital Subtraction Angiography. An In-Vitro and In-Vivo Study.

Authors:  N F Fanning; H M O'Dwyer; J A B Bowden; P R Brennan; J Thornton
Journal:  Interv Neuroradiol       Date:  2005-06-17       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.