A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Luis F Gutiérrez1, Cengizhan Ozturk, Elliot R McVeigh, Robert J Lederman.   

Abstract

X-ray images acquired on systems with image intensifiers (II) exhibit characteristic distortion which is due to both external and internal factors. The distortion is dependent on the orientation of the II, a fact particularly relevant to II's mounted on C arms which have several degrees of freedom of motion. Previous descriptions of distortion correction strategies have relied on a dense sampling of the C-arm orientation space, and as such have been limited mostly to a single arc of the primary angle, alpha. We present a new method which smooths the trajectories of the segmented vertices of the grid phantom as a function of a prior to solving the two-dimensional warping problem. It also shows that the same residual errors of distortion correction could be achieved without fitting the trajectories of the grid vertices, but instead applying the previously described global method of distortion correction, followed by directly smoothing the values of the polynomial coefficients as functions of the C-arm orientation parameters. When this technique was applied to a series of test images at arbitrary alpha, the root-mean-square (RMS) residual error was 0.22 pixels. The new method was extended to three degrees of freedom of the C-arm motion: the primary angle, alpha; the secondary angle, beta; and the source-to-intensifier distance, lambda. Only 75 images were used to characterize the distortion for the following ranges: alpha, +/- 45 degrees (Deltaalpha = 22.5 degrees); beta, +/- 36 degrees (Deltabeta = 18 degrees); lambda, 98-118 cm (Deltalambda = 10 cm). When evaluated on a series of test images acquired at arbitrary (alpha, beta, lambda), the RMS residual error was 0.33 pixels. This method is targeted at applications such as guidance of catheter-based interventions and treatment planning for brachytherapy, which require distortion-corrected images over a large range of C-arm orientations.

Mesh:

Year:  2008        PMID: 18404935      PMCID: PMC2679378          DOI: 10.1118/1.2839099

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  Correction for geometric image distortion in the x-ray imaging chain: local technique versus global technique.

Authors:  E Gronenschild
Journal:  Med Phys       Date:  1999-12       Impact factor: 4.071

2.  Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures.

Authors:  K Wiesent; K Barth; N Navab; P Durlak; T Brunner; O Schuetz; W Seissler
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

3.  A global method based on thin-plate splines for correction of geometric distortion: an application to fluoroscopic images.

Authors:  Silvia Fantozzi; Angelo Cappello; Alberto Leardini
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

4.  Three-dimensional motion tracking of coronary arteries in biplane cineangiograms.

Authors:  Guy Shechter; Frédéric Devernay; Eve Coste-Manière; Arshed Quyyumi; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2003-04       Impact factor: 10.048

5.  Distortion correction for x-ray image intensifiers: local unwarping polynomials and RBF neural networks.

Authors:  P Cerveri; C Forlani; N A Borghese; G Ferrigno
Journal:  Med Phys       Date:  2002-08       Impact factor: 4.071

Review 6.  Evolution of digital angiography systems.

Authors:  Raffaela Brigida; Teresa Misciasci; Fabiola Martarelli; Guido Gangitano; Pierfrancesco Ottaviani; Massimo Rollo; Pasquale Marano
Journal:  Rays       Date:  2003 Jan-Mar

7.  A system for real-time XMR guided cardiovascular intervention.

Authors:  Kawal S Rhode; Maxime Sermesant; David Brogan; Sanjeet Hegde; John Hipwell; Pier Lambiase; Eric Rosenthal; Clifford Bucknall; Shakeel A Qureshi; Jaswinder S Gill; Reza Razavi; Derek L G Hill
Journal:  IEEE Trans Med Imaging       Date:  2005-11       Impact factor: 10.048

8.  Correction of XRII geometric distortion using a liquid-filled grid and image subtraction.

Authors:  David W Holdsworth; Steven I Pollmann; Hristo N Nikolov; Rebecca Fahrig
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

9.  X-ray fused with magnetic resonance imaging (XFM) to target endomyocardial injections: validation in a swine model of myocardial infarction.

Authors:  Ranil de Silva; Luis F Gutiérrez; Amish N Raval; Elliot R McVeigh; Cengizhan Ozturk; Robert J Lederman
Journal:  Circulation       Date:  2006-11-13       Impact factor: 29.690

10.  On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

Authors:  Lizhong Liu; Daniel A Bassano; Satish C Prasad; Bonnie L Keshler; Seung S Hahn
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

View more
  8 in total

1.  Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures.

Authors:  Ashvin K George; Merdim Sonmez; Robert J Lederman; Anthony Z Faranesh
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

2.  Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.

Authors:  Alex George; Peter Y Chen; Alejandro Morales-Martinez; Alireza Panna; Andrew A Gomella; Eric E Bennett; Han Wen
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-24

3.  X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization.

Authors:  Yoav Dori; Marily Sarmiento; Andrew C Glatz; Matthew J Gillespie; Virginia M Jones; Matthew A Harris; Kevin K Whitehead; Mark A Fogel; Jonathan J Rome
Journal:  Circ Cardiovasc Imaging       Date:  2011-05-02       Impact factor: 7.792

4.  Multimodality calibration for simultaneous fluoroscopic and nuclear imaging.

Authors:  Casper Beijst; Mattijs Elschot; Sandra van der Velden; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2016-08-30

5.  Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.

Authors:  Angela E Kedgley; Anne-Marie V Fox; Thomas R Jenkyn
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

6.  Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

Authors:  Giulio Dagnino; Ioannis Georgilas; Samir Morad; Peter Gibbons; Payam Tarassoli; Roger Atkins; Sanja Dogramadzi
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-04       Impact factor: 2.924

Review 7.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

8.  Multi-body 3D-2D registration for image-guided reduction of pelvic dislocation in orthopaedic trauma surgery.

Authors:  R Han; A Uneri; M Ketcha; R Vijayan; N Sheth; P Wu; P Vagdargi; S Vogt; G Kleinszig; G M Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2020-07-17       Impact factor: 4.174

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.